Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction

Regulation 458. Dished Ends subject to internal pressure

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 774–775Formula / symbols

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

458. Dished Ends subject to internal pressure.─ (1) For unstayed ends of shells and tops of vertical boilers and the like boiler parts, when dished to partial spherical form the maximum allowable working pressure shall be determined by the following formula:

𝑃 = 0.216 𝑆(𝑡−0.79) Equation (12/7)

𝑅

Where, is the maximum allowable working pressure in kg/cm2(g), P = t = is the thickness of the end plate in mm but in no case this shall be less than the thickness of the shell to which it is attached,

R = is the inner radius of curvature of the end in mm, which shall not exceed the external diameter of the shell to which it is attached,

S = is the minimum tensile breaking strength of plate in kg/cm2, or whatever is allowed for it.

(2)The inside radius to which a crown plate is dished shall be not greater than the external diameter of the cylinder to which it is attached.

(3)The inside radius of curvature of the flanges to the shell shall be not less than 4 times the thickness of the crown plate and in no case less than 63 mm.

(4)The inside radius of curvature of flanges shall be not less than twice the thickness of the crown plate and in no case less than 25 mm.

(5)When the end has a manhole in it (t-3.97), shall be substituted for (t-0.79) in the formula.

(6)The total depth of flange of manhole from the outer surface measured on the minor axis shall be at least equal to -

√ (T x W) depth of flange in mm. Equation (12/8)

Where T is the thickness of the plate in mm and W is the minor axis of the hole in mm.

(7)The depth of the crown plate opening from the commencement of the curvature of the flanging radius shall be not less than twice the plate thickness with a minimum of 25 mm.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Sets the maximum allowable working pressure and flange rules for unstayed dished ends of shells and tops of vertical boilers dished to partial spherical form, under internal pressure.

Key points

  • (1) Pressure from Equation (12/7), using coefficient 0.216, tensile strength S, thickness t (less 0.79) and inner radius R. t must not be less than the shell thickness, and R must not exceed the external diameter of the shell.
  • (2) The inside dishing radius of a crown plate must not exceed the external diameter of its cylinder.
  • (3) Inside radius of the flanges to the shell: at least 4 times the crown plate thickness and never less than 63 mm.
  • (4) Inside radius of flanges: at least twice the crown plate thickness and never less than 25 mm.
  • (5) If the end has a manhole, (t-3.97) replaces (t-0.79) in the formula.
  • (6) The total manhole flange depth on the minor axis must be at least √(T × W) (Equation 12/8).
  • (7) The depth of the crown plate opening from the start of the flange curvature must be at least twice the plate thickness, with a minimum of 25 mm.

Watch out

  • See regulation 459: dished ends complying with regulations 174 to 177 may still be used where no uptake is fitted. For external pressure, see regulation 460.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Worked example (educational, engineering review pending)

Dished end maximum allowable working pressure, Equation (12/7) (regulation 458)

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
567Dished ends subject to internal pressure100%Chapter XII (DPIIT scan), image 4
568Dished ends subject to external pressare92%Chapter XII (DPIIT scan), image 4
198Dished ends subject to external gee e co80%Chapter IV (DPIIT scan), image 4
IBR 1950 regulation 567 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 567 page for its amendments.

Reg. 567, Reg. 567A

Dished ends subject to internal pressure

a)

For unstayed ends of shells and tops of vertical boilers and the like boiler parts, when dished to partial spherical form the maximum working pressure shall be determined by the following formula:-

WP = 15 x S X (t-1)
Equation XII/7
R

WP is the working pressure in pounds per square inch.

t is thickness of the end plate in thirty seconds of an inch but in no case this shall be less than the thickness of the shell to which it is attached.

R is the inner radius of curvture of the end in inches, which shall not exceed the external diameter of the shell to which it is attached.

S is the minimum tensile breaking strength of plate in tons per square inch, or whatever is allowed for it.
b) The inside radius to which a crown plate is dished shall be not greater than the external diameter of the cylinder to which it is attached.
c) The inside radius of curvature of the flanges to the shell shall be not less than 4 times the thickness of the crown plate and in no case less than 2 ½ inches.
d) The inside radius of curvature of flanges to uptakes shall be not less than twice the thickness of the crown plate and in no case less than 1 inch.
e) When the end has a manhole in it (t-5), shall be substituted for (t -1) in the formula.
f) The total depth of flange of manhole from the outer surface in inches measured on the minor axis shall be at least equal to-

ÖT X W depth of flange in inches Equation XII/8

where T is the thickness of the plate in inches and W is the minor axis of the hole in inches.
g) The depth of the crown plate opening from the commencement of the curvature of the flanging radius shall be not less than twice the plate thickness with a minimum of one inch.


Reg. 567A

Nothing in Regulation 567 shall preclude the use of dished ends in compliance with Regulations 275 to 278, where not fitted with an uptake.
IBR 1950 regulation 568 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 568 page for its amendments.

Reg. 568, Reg. 569, Reg. 570

Dished ends subject to external pressure

In the case of unstayed dished ends for the coefficient 15 in Equation XII/7, the coefficient 12 shall be substituted, and R shall be the outer radius of the curvature of plate, which shall not exceed the external diameter of the shell to which it is attached.

For plates exposed to furnace-flame the coefficient shall be 10.5. In no case shall
R/t  exceed 2.75.

The inside radius of curvature at the flange shall be not less than 4 times the thickness of the end plate and in no case less than 2 ½ inches.

The inside radius of the curvature of the flange to uptake shall be not less than twice the thickness of the crown plate and in no case less than one inch.



Reg. 569

Hemispherical crowns

 The maximum working pressure for hemispherical crowns subjected to internal pressure shall be determined by the following formula:-

WP = (t-2) S x C Equation XII/9
R

Where,

t is thickness of plate in thirty-seconds of an inch.
WP is the working pressure in pounds per square inch.
R is inner radius of curvature in inches.
S is minimum tensile strength of the plate in tons per square inch.
C is a constant, as given below.

In no case, however, shall the factor of safety of the crown plate be less than 4 nor the plate thickness be less than specified in Table given under Regulation 563.

C=32 where Class I requirements are complied with.
C=27 where Class II requirements are complied with.
C=23 for Class III boilers when stress relieved.
C=21 for Class III boilers when not stress relieved.


Reg. 570

Manholes and other openings in shells

Manholes and other openings in shells shall be placed as far as possible from any seam. Wherever practicable oval openings shall be arranged with the minor axis parallel with the longitudinal centre line of the boiler. In no case shall the circumferential length of any opening exceed twice the longitudinal width of the opening.
IBR 1950 regulation 198 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 198 page for its amendments.

Reg. 198, Reg. 199, Reg. 200
FLAT PLATES


Circular flat ends of drums, etc., supported only at edges

a) For these ends C in Equation 35 shall be taken as 140 when the plates are not exposed to flame, and 122.5 when they are exposed to flame. In this case the circle D shall pass through the centres of rivets or bolt securing the end be less than 4 times, the thickness of the end plate but in no case less curvature.
b) Where flanged the inside radius of curvature at the flange shall not be less than 4 times, the thickness of the end plate but in no case less than 2-1/2".



Reg. 199
FLAT PLATES


Bar or bulb stiffened end plates and smoke-box tube plates of Loco-type boilers

Where such plates instead of being supported by stays are stiffened in the steam space by substantial tee or angle bars securely riveted to the plate and extending across the plate to within the margin allowed by the Equation(35) or where such plates are formed with a deep bulb extending across the plate to well within the margin allowed, for the support thus given.

C shall be taken as equal to 80 and 70 for plates not exposed, and exposed to flame respectively. The margin or pitch for such stiffening shall be measured from the centre line of rivets or commencement of curvature of bulb provided it is not more than 2 inches from the centre line of bulb.

For the flat plate above the stiffener or bulb, C shall be taken as the mean of the values appropriate for the points of support.

Reg. 200
FLAT PLATES


Flat plate margins

The amount of support in relief of stays which may be credited to the sides of shells, furnaces, uptakes, fireholes and foundries rings to which flat plates are attached shall not exceed that found by the following formula :
Width of margin in inches = C ( t - 1 ) Eqn.(37)
         (W. P)1/2

where
t = thickness is 32nds of an inch

W. P. = Working pressure in lbs. per sq. inch.

C = 3.47 for plates exposed in flame.

C = 3.70 for plates not exposed to flame.

Where the plates are flanged the margin shall be measured from the commencement of curvature or from a line 2-1/2 times the thickness of the plate distant from the side of the flange next to the inner radius of the corner whichever is the less. In other cases, the margin shall be measured from the centre line of rivets in the nearest row of the seam by which the flat plate is attached.

Doubling plates shall cover the area supported between the stays and extend beyond the stays so that the centre of the rivets securing the doubling plate to the end plate shall be at least half the distance from the outermost stays to the nearest substantial point of support.

Where flat end plates are flanged for connection to the shell the inside radius of flanging shall be not less than 1.75 times the plate thickness with a minimum of 1-1/2 inches.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
774–775
PDF page index
774–775 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 709eb6bd30d5e42f
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log