Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction

Regulation 496. Corrugated fireboxes of vertical boilers

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 794Formula / symbols

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

496.Corrugated fireboxes of vertical boilers.─ (1) For the semi-spirally corrugated fireboxes of ‘Sentinel’ standard motor wagon boilers the maximum allowable working pressure shall be determined by the following formula:

𝑃 = 𝐶 (32 𝑡−25.4) Equation (12/30)

𝐷

Where,
P is maximum allowable working pressure in kg/cm2(g)
t is thickness of the firebox plate in mm
D is mean of the external diameters of firebox measured over the plain part at each end at commencement of curvature of flange in mm
C = 27.41972

(2)No corrugated furnace shall be less than 10 mm thick.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 496 gives the pressure formula for the semi-spirally corrugated fireboxes of "Sentinel" standard motor wagon boilers, and a minimum thickness for corrugated furnaces.

Key points

  • (1) Maximum allowable working pressure P (kg/cm² (g)) comes from Equation (12/30), with:
  • t, the firebox plate thickness (mm);
  • D, the mean of the external diameters measured over the plain part at each end, at the commencement of flange curvature (mm);
  • C = 27.41972.
  • (2) No corrugated furnace may be less than 10 mm thick.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
594Corrugated Fireboxes of Vertical Boilers100%Chapter XII (DPIIT scan), image 14
221Corrugated Furnaces of Horizontal Boilers77%Chapter IV (DPIIT scan), image 14
596Foundations of Vertical Boiler Furnaces71%Chapter XII (DPIIT scan), image 14
IBR 1950 regulation 594 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 594 page for its amendments.

Reg. 593, Reg. 594, Reg. 595

Plain Furnaces of Vertical Boilers

The maximum working pressure of Plain Furnaces of Vertical boilers shall be the lesser of the two values obtained by Equations XII/25 and XII/26.

Where,

D = external diameter of the firebox in inches. Where the firebox is tapered the diameter taken shall be the mean of that at the top and at the bottom where it meets the substantial support from the flange or ring.

L is length of the firebox in inches between points of substantial support measured from the commencement of flange curvature or from the foundation connection, or from a row of screwed stays which comply with Regulations 550(b), 585(b), whichever is applicable.

In no case, however, shall the thickness be more than 7/8 inch. For fireboxes under 2 feet and 6 inches in diameter, the thickness shall be not less than 5/16 inch and for fireboxes 2 feet and 6 inches in diameter and over the thickness shall be not less than 3/8 inch.


Reg. 594

Corrugated Fireboxes of Vertical Boilers

For the semi-spirally corrugated fireboxes of ‘Sentinel’ standard motor wagon boilers the working pressure shall be determined by the following formula-

W.P. = C(t-1) Equation XII/29
D

W.P. is working pressure in pounds per square inch.
t is thickness of the firebox plate in thirty seconds of an inch.
D is mean of the external diameters of firebox measured over the plain part at each end at commencement of curvature of flange.
C = 390.

No corrugated furnace shall be less than 3/8 inch thick.
 

Reg. 595

Hemispherical Furnaces of Vertical Boilers

When furnaces are hemispherical in form and subject to pressure on the convex side and are without support from stays of any kind the maximum working pressure shall be found by the following formula:-

W.P. = 275(t-1) Equation XII/30
R

W.P. is working pressure in pounds per square inch.
t is thickness of the top plate in thirty seconds of an inch.
R is outer radius of curvature of the furnace in inches.
The thickness of these furnaces shall in no case exceed 7/8 inch
IBR 1950 regulation 221 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 221 page for its amendments.

Reg. 220, Reg. 221, Reg. 222

FURNACES

Plain Furnaces of Horizontal Boilers

For plain furnaces or furnaces strengthened by Adamson or other joints or stiffeners of sufficient strength and for the semi-cylindrical tops of fire-boxes and bottom of combustion chambers where the sides are securely stayed, the working pressure shall not exceed the smaller of the values obtained from the following formulae :-
W. P. = C X (t - 1)2 Eqn.(57)
D ( L + 24 )

W. P. = C1 X {10 ( t - 1) - L ) Eqn.(58)
D

Where
d = the external diameter of the furnace or chamber top or bottom in inches

t = the thickness of the furnace plate in 32nds of an inch.

L = the length of the furnace or other part in inches measured between points of substantial support, i.e. centres of rows of rivets in end seams or commencement of curvature of flange, whichever is applicable.

C = 1450 where the longitudinal seams of steel furnaces are welded and 1300 where they are riveted,

C = 725 where the longitudinal seams of circular copper fireboxes or furnaces are fitted with double butt straps and 650 where they are lapped,

C1 = 50 where the longitudinal seams of steel furnaces are welded and 45 where they are riveted,

C1 = 25 where the longitudinal seams of circular copper fireboxes or furnaces are fitted with double butt straps and 22.5 where they are lapped.

Reg. 221

FURNACES

Corrugated Furnaces of Horizontal Boilers

The maximum working pressure to be allowed on corrugated furnaces shall be determined by the following formula -
W. P. = C ( t - 1 ) Eqn.(59)
D

where
D is the least external diameter in inches measured at the bottom of the corrugations on the water side.

t is the thickness of the furnace plate in 32nds of an inch measured at the bottom of the corrugation or chamber,

C = 480 for the Fox, Morrison, Deighton, Purves,, and other similar furnaces and 510 for the leeds Forge Bulb Suspension Furnace.

Reg. 222

FURNACES

Plain Furnaces of Vertical Boilers

The same formulae as for the plain furnaces of horizontal boilers shall be used, but where the furnaces are tapered the diameter to be taken for calculation purposes shall be the mean of that at the top and of that at the bottom where it meets the substantial support from flange or ring. The length for the same purpose shall be the distance from the centre of the row of rivets connecting the crown and the body of the furnace to the substantial support at the bottom of the furnace, or to a row of screwed stays connecting the furnace to the shell, provided that the pitch of stays at the furnace does not exceed 14 times the thickness of the furnace plate when the stays are riveted at their ends or 16 times when the stays are fitted with nuts. Such screwed stays shall be in diameter over the threads not less than twice the thickness of the furnace plate and in no case less than 3/4" diameter {See Reg.135 (d)}.
IBR 1950 regulation 596 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 596 page for its amendments.

Reg. 596, Reg. 597

Foundations of Vertical Boilers Furnaces

When circular furnaces of fireboxes of vertical boilers are not connected to the shell crown by uptake tube, smoke tubes or bolt stays and the whole load on the firebox vertically is borne by the bottom part of the firebox where it is connected to the shell the working pressure for the part, if firebox is joggled out to meet the shell or if any ogee ring is fitted, shall not exceed that found by the following formula:-

W.P. = C(t-1)² Equation XII/31
D(D-D1)

W.P. is working pressure in pounds per square inch.
t is thickness of the joggled firebox plate or ogee ring in thirty seconds of an inch.
D is inside diameter of the boiler shell in inches.
D1 is outside diameter of the joggled firebox at the commencement of curvature
Above joggled part or the outside diameter of the firebox where it joins the ogee ring.
C = 140 for Ogee rings (see Fig XII/26 and XII/27.
C = 100 where ‘U’ ring section is used (see Fig. XII/28)


Reg. 597

Foundations of Loco-type Boiler Fireboxes

Where the firebox roof in loco-type boilers is, not stayed direct to the external casing crown or to girders carried by the casing or if not connected to the casing by slings the working pressure for the parts, if plates are joggled out to meet the casing or if an ogee ring is fitted, shall not exceed that found by the following formula:-

W.P. = 70 (t-1) x (L+W)
Equation XII/32
L+W(W-W1)

WP is working pressure in pounds per square inch.
t  is thickness of the joggled firebox side plates or fire hole plate (whichever is less) or ogee ring in thirty seconds of an inch.
L  is length of firebox casing in inches measured between the water sides of front end plate and saddle plate at the foundation seam.
W  is width of firebox casing in inches measured between the water side of casing side plates at the foundation seam.
W1  is width of firebox in inches measured between the water sides of firebox side plates at the commencement of curvature above joggled part or where it joins the ogee ring.


Where only a comparatively narrow strip of the firebox roof is stayed directly to the casing crown the area so stayed shall be deducted from the area represented by LXW in the bottom line of the formula thus:

(L X W – A)(W-W1) and so used in Equation XII/32 in determining the working pressure for the parts, “A” being the area in square inches of the part of roof supported by the casing crown.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
794
PDF page index
794 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash fbe702b69a44ccfc
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 496, Regulation 496, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.794. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.