Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 415. Bar stays
Not yet checked against the official Gazette; verify before relying on it.
415.Bar stays.─ (1)Plain bars, passing through clearing holes in the plates and welded thereto (see Figure 12/50).
(2)Plain bars passing through clearing holes in the plates and fitted with washers on the outside, the stay and washers being welded to the plates in accordance with any one of the methods shown in Figures 12/52, 12/53, 12/54, 12/55, 12/56, 12/57, 12/58, 12/59.
Note: Clearing hole for the purpose of this regulation mean a machined cylindrical hole having a diameter not exceeding that of bar stay by more than 2%.
Figures cited in this regulation (9, exact crops of the Gazette)

View Gazette page 809 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 809 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 810 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 810 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 811 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 811 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 811 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 811 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 812 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
In short
Regulation 415 sets the permitted ways of securing bar stays to plates.
Key points
- (1) Plain bars through clearing holes in the plates, welded to the plates (Figure 12/50).
- (2) Plain bars through clearing holes with washers on the outside, the stay and washers welded to the plates by one of the methods shown in the listed figures.
Watch out
- Note: a "clearing hole" here means a machined cylindrical hole whose diameter does not exceed the bar stay's by more than 2%.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 134 | Diagonal Bar or Rod Stays | 100% | Chapter III (DPIIT scan), image 6 |
| 588 | Loads on Stay Tubes and Bar Stays | 100% | Chapter XII (DPIIT scan), image 11 |
| 30 | Stay Bars | 89% | Chapter II (DPIIT scan), image 3 |
IBR 1950 regulation 134 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 134 page for its amendments.
| Reg. 133, Reg. 134 STAYS Jointed Stays Where jointed longitudinal stays are fitted, they shall, where practicable, be fitted with pins having an effective sectional area 25 per cent in excess of that of the stay. If the pins are slack in the holes, the total slackness shall not be more than 1/6 inch. The pins shall be as close as possible to the shoulder of the eye forging. The shoulder of the forging shall be at least ½ inch wide all round, i.e., the diameter at the shoulder shall be not less than the diameter of the hole plus 1 inch . Reg. 134 STAYS Diagonal Bar or Rod Stays The sectional area of diagonal rod or bar stay shall bear the same proportion to that of a direct stay as the length of the diagonal stay bears to the length of the perpendicular line from the end of the diagonal stay to the surface supported. The ends of diagonal stays, shall not be bent, but shall be attached to the plate with revelled washers and nuts or with riveted tee, blocks or angles and shackle pins (see Regulation 133 for eyes and pins). |
IBR 1950 regulation 588 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 588 page for its amendments.
| Reg. 587, Reg. 588 | |||||||||||||||||||||||||||||||||
Reg. 588 Loads on Stay Tubes and Bar Stays
| |||||||||||||||||||||||||||||||||
IBR 1950 regulation 30 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 30 page for its amendments.
| Reg. 30 MATERIALS OF CONSTRUCTION WROUGHT IRON STAY AND RIVET BARS |
| The tensile breaking strength shall be between 21 and 25 tons with an elongation of not less than 22 per cent measured on the Standard Test Piece B or 27 per cent measured on the Standard Test Piece B1. |