Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 436. Test of Class I boilers
Not yet checked against the official Gazette; verify before relying on it.
436.Test of Class I boilers .─(1) Specimens for the following tests shall be selected from the test plate or plates and stamped by the Competent Person for identification (see Figures 12/71 and 12/72).
(i)One tensile test specimen for the welded seam.
(ii)One all weld metal tensile test specimen.
(iii)Two bend test specimens.
(iv)Two impact test specimens.
(v)One specimen from each test plate for macro examination.
(2)The dimensions of the specimens shall be in accordance with the sketches in Figures 12/73, 12/74, 12/76,12/77 and 12/78. The remainder of the test plates shall be retained for re-tests, if required. Any specimen for re-test shall be cut from the same test plate as the original specimen. Specimens representing welded seams shall, if necessary, be straightened cold before the commencement of machining. Tensile and bend specimens shall, if practicable, be of the full plate thickness. Surfaces of tensile, bend and Charpy specimens corresponding with the outside or inside of the boiler shall be lightly dressed only so that the rolled surface of the parent metal is not wholly removed. Where the rolled surfaces of the abutting plates are not level with one another one plate may be machined at each face of the weld so long as the depth of the metal removed does not exceed 0.8 mm.
Figures cited in this regulation (7, exact crops of the Gazette)

View Gazette page 815 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 816 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 816 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 817 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 817 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 818 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 819 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
In short
Lists the test specimens required from the test plates for Class I boilers and how they are prepared.
Key points
- (1) Specimens are selected from the test plate(s) and stamped by the Competent Person (Figures 12/71 and 12/72):
- one tensile specimen for the welded seam;
- one all weld metal tensile specimen;
- two bend specimens;
- two impact specimens (as printed; note that the acceptance rule in regulation 162, applied through regulation 439, is based on the average of three specimens, so check the number with the Inspecting Authority);
- one macro examination specimen from each test plate.
- (2) Dimensions follow Figures 12/73, 12/74 and 12/76 to 12/78. The rest of the test plate is kept for re-tests, and any re-test specimen must come from the same test plate.
- (2) Seam specimens may be straightened cold before machining. Tensile and bend specimens are full plate thickness where practicable.
- (2) Surfaces matching the boiler's outside or inside are only lightly dressed, so the rolled surface is not wholly removed. Where abutting plates are not level, one plate may be machined at each face of the weld, removing no more than 0.8 mm.
The individual tests are in regulation 437 (tensile), regulation 438 (bend), regulation 439 (impact) and regulation 440 (macro and micro).
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 436, Regulation 436, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.766–767. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.