493. Stiffeners.─ (1) Stiffeners shall have second moment of inertia not less than that given by the following equation:
Pd3 L Equation (12/29)
Is = ----------------
1.35 x 107
(2)(a)If the stiffeners are made in sections from bar or plate, the abutting ends shall be prepared so as to ensure that full penetration welds are made.
(b)The thickness of the stiffening ring shall be kept to the minimum required (for limiting dimensions see Figures 12/29 and 12/30).
(3)Bowling hoops are considered as effective points of support. The minimum pitch of bowling hoop centres shall be not less than 500 mm. If bowling hoops are used, the furnace thickness shall be calculated from regulation 488. The dimensions of bowling hoops shall be in accordance with figures 12/120(Fig. A , Fig B and Fig C)and their second moment of area determined from the tables given in these figures, shall be not less than required by sub-regulation (1).
(4)If corrugated furnaces are equipped with several stiffeners, e.g. one on each corrugation or on each second corrugation, the cross-sectional area and the second moment of area of the stiffeners shall also be taken into consideration when using the equation 12/27. A height of not more than four times the furnace thickness shall be used for the calculation.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
Figures cited in this regulation (3, exact crops of the Gazette)

View Gazette page 804 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 804 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 835 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 493 sets the stiffness and construction rules for furnace stiffeners and bowling hoops.
Key points
- (1) Each stiffener's second moment of area must be at least the value from Equation (12/29), which uses P, d and L.
- (2)(a) Stiffeners made in sections from bar or plate need abutting ends prepared for full penetration welds.
- (2)(b) Keep the stiffening ring thickness to the minimum required. Limiting dimensions are in Figures 12/29 and 12/30.
- (3) Bowling hoops count as effective points of support. Their centres must be at least 500 mm apart. With bowling hoops, furnace thickness is calculated under regulation 488. Hoop dimensions follow Figure 12/120, and their second moment of area from the tables in those figures must meet sub-regulation (1).
- (4) Where a corrugated furnace has several stiffeners, include their cross-sectional area and second moment of area in Equation (12/27) of regulation 490. Use a stiffener height of no more than four times the furnace thickness in the calculation.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 493, Regulation 493, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.793. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.