Regulation 474. Compression of Tube Plates
Not yet checked against the official Gazette; verify before relying on it.
474.Compression of Tube Plates.─ (1) For fire-box or combustion chamber tube plates which are subject to compression due to the pressure on the roof plate, the maximum allowable working pressure shall be:
𝑃 = 𝐶 (𝑝−𝐷) 32 𝑡 Equation (12/15)
Where, 𝐿 𝑝 t is thickness of the tube plate in mm.
p is pitch of the tubes in mm, measured horizontally where the tubes are chain pitched or diagonally where the tubes are zigzag pitched and the diagonal pitch is less than the horizontal.
D is internal diameter of the plain tubes in mm.
L is internal length of the fire-box or combustion chamber in mm measured at top between tube plate and Firehole plate or back plate, or between tube plates in double ended boilers with combustion chambers common to two opposite furnaces.
C = 61.16706
Provided that the above formula shall not apply in the cases of fire-boxes where the girders do not rest on the tube plate, or where the roof plate is stayed direct to the outer shell or to girders supported by the shell.
(2)Where girders rest on the side plates or the roof plate is so formed that the load is carried both by side and end plates, the compressive stress on the plates shall not in either case exceed 984 kg/cm2.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Sets the maximum allowable working pressure for fire-box and combustion chamber tube plates under compression from the pressure on the roof plate.
Key points
- (1) Pressure from Equation (12/15), with C = 61.16706, t (tube plate thickness), p (tube pitch), D (internal diameter of plain tubes) and L (internal length of the fire-box or combustion chamber at the top), all in mm.
- (1) p is measured horizontally for chain pitching, or diagonally for zigzag pitching where the diagonal pitch is less than the horizontal.
- (2) Where girders rest on the side plates, or the roof plate carries load to both side and end plates, compressive stress on the plates must not exceed 984 kg/cm2.
Watch out
- The formula does not apply to fire-boxes where the girders do not rest on the tube plate, or where the roof plate is stayed directly to the outer shell or to girders supported by the shell.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 33 | Plates | 100% | Chapter II (DPIIT scan), image 3 |
| 118 | Tube Plates | 100% | Chapter III (DPIIT scan), image 2 |
| 582 | Compression of tube plates | 100% | Chapter XII (DPIIT scan), image 9 |
IBR 1950 regulation 33 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 33 page for its amendments.
| Reg. 33 MATERIALS OF CONSTRUCTION COPPER PLATES, STAY AND RIVET BARS |
| (a) Process.- The copper shall be fire-refined or electrolytic and hot-rolled from suitable cakes. (b) Chemical Composition.- The chemical composition of the plates shall be as follows:-
(c) Freedom from defects.- The plates shall be clean, smooth and free from defects and shall have a workmanlike finish. They shall be thoroughly annealed. (d) Rolling Margin.- No plate shall be under the specified thickness at any part, not more than 5% over the calculated weight. The scrap margin, partly sheared and left attached, shall be not less than 3 inches at the ends and 1½ inches at each side. (e) Tensile Tests.- One tensile test shall be taken from each plate as rolled. The tensile breaking strength, from Standard Test Piece A, shall not be less than 14 tons per sq. inch with an elongation of not less than 35%. (f) Hot and Cold Bend tests.- One hot (temperature between 1200°F and 1400°F) and one cold bend test shall be taken from each plate as rolled. For either hot or cold bend tests, the test piece shall withstand being doubled over without fracture until the sides are touching and parallel. |
IBR 1950 regulation 118 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 118 page for its amendments.
| Reg. 118, Reg. 119, Reg. 120 END PLATES
Tube Plates Parts of flat tube plates within the tube nests
Reg. 120 END PLATES Flanging of End Plates All flanges shall be a good fit to the shell and flues. Flogging and/or hammering in the fitting of these parts is prohibited. The caulking edges of all flanged plates shall be machined or machine gas cut. |
IBR 1950 regulation 582 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 582 page for its amendments.
| Reg. 582, Reg. 583, Reg. 584 | |||||||||||||||||||
Reg. 583 Girders for fire-box and combustion chamber crowns
Reg. 584 Girder sling stays
| |||||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 474, Regulation 474, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.782–783. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.