| Reg. 118, Reg. 119, Reg. 120 END PLATES
Tube Plates Parts of flat tube plates within the tube nests
Reg. 120 END PLATES Flanging of End Plates All flanges shall be a good fit to the shell and flues. Flogging and/or hammering in the fitting of these parts is prohibited. The caulking edges of all flanged plates shall be machined or machine gas cut. |
Earlier text: the 2008 DIPP web edition
END PLATES
GENERAL
Tube Plates
Smoke-box tube plates shall be flanged for attachment to the barrel or shall be flat and connected thereto by an external riveted angle ring.
Possible IBR 2026 successors (heading match, unverified): Reg. 31, Reg. 77, Reg. 78, Reg. 79, Reg. 91, Reg. 92, Reg. 149, Reg. 402, Reg. 406, Reg. 430, Reg. 456, Reg. 469, Reg. 474, Reg. 575