Regulation 119 — Parts of flat tube plates within the tube nests

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 118, 120. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 118, Reg. 119, Reg. 120
END PLATES

 

Tube Plates

Smoke-box tube plates shall be flanged for attachment to the barrel or shall be flat and connected thereto by an external riveted angle ring.

Reg. 119
END PLATES

 

Parts of flat tube plates within the tube nests

a) where the total area of all tube nests in directly fired multi-tubular boilers exceeds 7 sq. ft., stay tubes shall be fitted.

Where the total number of tubes in horizontal multitubular waste heat boilers and direct fired loco type boilers is arranged in one next, the area of which exceed 21 sq. ft., stay tubes shall be fitted.

In all cases where the total number of tubes is arranged in more than one nest, stay tubes shall be fitted.
b) The parts of tube plates which lie outside the nests of tubes shall be stayed or supported wherever the size of the area of plate subject to steam pressure necessitates staying or support, either by marginal stay tubes or other means.


Reg. 120
END PLATES
Flanging of End Plates

All flanges shall be a good fit to the shell and flues. Flogging and/or hammering in the fitting of these parts is prohibited. The caulking edges of all flanged plates shall be machined or machine gas cut.

Earlier text: the 2008 DIPP web edition

END PLATES

GENERAL

Parts of flat tube plates within the tube nests

a)where the total area of all tube nests in directly fired multi-tubular boilers exceeds 7 sq. ft., stay tubes shall be fitted.

Where the total number of tubes in horizontal multitubular waste heat boilers and direct fired loco type boilers is arranged in one nest, the area of which exceed 21 sq. ft., stay tubes shall be fitted.

In all cases where the total number of tubes is arranged in more than one nest, stay tubes shall be fitted.

b)The parts of tube plates which lie outside the nests of tubes shall be stayed or supported wherever the size of the area of plate subject to steam pressure necessitates staying or support, either by marginal stay tubes or other means.