Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 484. Forboilers as per clause (d) of sub-regulation (9) of regulation 407
Not yet checked against the official Gazette; verify before relying on it.
484.Forboilers as per clause (d) of sub-regulation (9) of regulation 407.─ (1) Stays shall give breathing spaces around the furnace connections and tube nests (see Figures 12/86 to 12/93, 12/96, 12/97, 12/98, 12/99 and 12/100) and equally divide the unstayed areas. Breathing spaces between furnace and tube nests shall be a minimum of 50 mm or 5% of the shell outside diameter, whichever is larger, but need not be more than 100 mm.
(2)Breathing spaces between furnace and shells shall be as given in Table 12/9 or 12/10 as applicable, but shall be not less than 50 mm or, for bowling hoop furnace, not less than 75 mm as measured from the outside diameter of the bowling hoop.
(3)For the boilers having more than one furnace, breathing spaces between furnaces shall be not less than 120 mm.
(4)Breathing spaces between gusset or link stays and furnaces shall be not less than 200 mm, except for as under;
| Shell outside diameter | >1800 mm 250 mm |
| or furnace length | >6000 mm |
| Shell outside diameter | <1400 mm 150 mm |
| or furnace length | <3000 mm |
Table structure read from the Gazette PDF, page 787. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Shell outside diameter >1800 mm 250 mm or furnace length >6000 mm Shell outside diameter <1400 mm 150 mm or furnace length <3000 mm
(5)Breathing spaces between gusset or link stays and tube nests shall be not less than 100 mm.
(6)When unflanged flat endplates as used, the breathing spaces between gusset or link stay and furnaces shall be increased as follows:
Increase 200 mm to 220 mm
Increase 250 mm to 275 mm
Increase 150 mm to 165 mm
Increase 100 mm to 110 mm
(7)All other breathing spaces shall be a minimum of 50 mm or 3% of the shell outside diameter whichever is larger but need not be more than 100 mm.
Table 12/10: Breathing spaces between furnaces and shells when tube plate thickness does not exceed 25 mm
(Also see Table 12/11)
| Design | Length between the boiler end plates L in meter | Breathing space | |
|---|---|---|---|
| % of outside diameter (Note) | Maximum mm | ||
| (1) | (2) | (3) | (4) |
| Inserted flat ends | < 5.5 | 5 | 100 |
| 5.5 < L< 6.0 | 5.5 | 110 | |
| 6.0 < L< 6.5 | 6 | 120 | |
| Flanged ends | Any length | 5 | 100 |
Table structure read from the Gazette PDF, page 788. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Design Length between the boiler end plates L Breathing space
in meter
% of outside Maximum
diameter (Note) mm
(1) (2) (3) (4)
Inserted flat ends < 5.5 5 100
5.5 < L< 6.0 5.5 110
6.0 < L< 6.5 6 120
Flanged ends Any length 5 100Note: But not less than 50 mm or, for bowling hoop furnaces 75 mm.
(8)When the actual thickness of the end plate exceeds 25 mm, the breathing spaces in accordance with Table 12/10 shall be increased in accordance with Table 12/11.
Table 12/11: Breathing spaces between furnaces and shells when the thickness of the end plate exceeds 25 mm
| Length of furnace in meter | Breathing space | |||
|---|---|---|---|---|
| % of d. | Need note be more than mm | Minimum mm | ||
| (1) | (2) | (3) | (4) | (5) |
| < 5.5 | 6.5 | 130 | 65 | |
| 5.5 < L | < 6.0 | 7.0 | 140 | 70 |
| 6.0 < L | < 6.5 | 8.0 | 150 | 75 |
Table structure read from the Gazette PDF, page 788. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Length of furnace in (2) % of d. Breathing space Minimum
meter < 5.5 Need note be more mm
< 6.0 (3) (5)
(1) < 6.5 6.5 than mm 65
7.0 (4) 70
5.5 < L 8.0 130 75
6.0 < L 140Original extracted text of the table above, continued (diagnostic)
150
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
Figures cited in this regulation (13, exact crops of the Gazette)

View Gazette page 822 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 823 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 823 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 824 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 823 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 823 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 824 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 825 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 826 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 825 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 825 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 825 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 826 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 484 sets breathing spaces for boilers built under clause (d) of sub-regulation (9) of regulation 407 (the longer plain furnaces). Stays must give breathing space around furnace connections and tube nests and divide the unstayed areas equally.
Key points
- (1) Furnace to tube nests: at least 50 mm or 5% of the shell outside diameter, whichever is larger. It need not be more than 100 mm.
- (2) Furnace to shell: as in Table 12/9 or 12/10, as applicable, but at least 50 mm. For a bowling hoop furnace, at least 75 mm measured from the outside diameter of the hoop.
- (3) Between furnaces, where there is more than one: at least 120 mm.
- (4) Gusset or link stays to furnaces: at least 200 mm. It becomes 250 mm where shell outside diameter is over 1800 mm or furnace length is over 6000 mm, and 150 mm where shell outside diameter is under 1400 mm or furnace length is under 3000 mm. If a boiler meets a condition for both 250 mm and 150 mm, the larger clearance is the safe reading.
- (5) Gusset or link stays to tube nests: at least 100 mm.
- (6) With unflanged flat end plates, the gusset or link stay spaces increase: 200 mm to 220 mm, 250 mm to 275 mm, 150 mm to 165 mm and 100 mm to 110 mm.
- (7) All other breathing spaces: at least 50 mm or 3% of the shell outside diameter, whichever is larger, but need not be more than 100 mm.
- Table 12/10 covers furnace-to-shell spaces where tube plate thickness does not exceed 25 mm. It gives a percentage of outside diameter and a maximum, by design (inserted flat ends or flanged ends) and length L between end plates.
- (8) Where the end plate is thicker than 25 mm, the Table 12/10 spaces are increased in line with Table 12/11.
Watch out
- This regulation uses the shell outside diameter. Regulation 483 uses the inside diameter.
- Table 12/11 did not extract cleanly. Check the Gazette page for the exact values.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 484, Regulation 484, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.787–788. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.