Regulation 482. Breathing space

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 786

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

482. Breathing space.─ Breathing spaces as provided in regulations 483,484 or 485shall be provided depending on the design of the boiler with special attention to the provision of sub-regulation (9) of regulation 407 regarding furnaces.

Referenced provisions

Reg. 407 · Reg. 483 · Reg. 484 · Reg. 485

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 482 says breathing spaces must be provided as set out in regulation 483, regulation 484 or regulation 485, depending on the design of the boiler. It points you to sub-regulation (9) of regulation 407 on furnaces, which decides which of those regulations applies.

Key points

  • Clause (c) of sub-regulation (9) of regulation 407 links boilers made under clause (a) of that sub-regulation to the breathing spaces in regulation 483.
  • Clause (d) of sub-regulation (9) of regulation 407 links boilers with longer plain furnaces allowed under that clause to the breathing spaces in regulation 484.
  • Boilers not covered by regulations 483 and 484 follow regulation 485.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
141Breathing d furnace Conner a the table below are re75%Chapter III (DPIIT scan), image 7
IBR 1950 regulation 141 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 141 page for its amendments.

Reg. 141
GIRDER STAYS
Breathing Space

a) Gusset stays shall be so arranged as to allow sufficient breathing space around furnace connections and tube nests.
b) For Lancashire boilers the proportions shown in the table below are recommended for the portion of the end plates above the furnaces and flues.

Thickness of End Plates L-
(Fig.8)
L-
(Fig.9)
Inches Inches Inches
½ 9 10
9/16 10 10
5/8 11 12
11/16
¾
13/16
12 13
Above 13/16 12½ 13½
c) Fig. 8 shows the breathing space recommended for the following conditions: Flat end, furnace or flues flanged for attachment to end plate, furnaces and flues formed with Adamson flanged seams.
d) Fig. 9 shows similar conditions to Fig. 8 except that the end plate is flanged outwards for the furnace or flue ring connection, the breathing spaces allowed being 1 inch more than those for the same thickness of plate in Fig.8.
e) Where a corrugated section not less than 6 feet long is included in each internal flue of a Lancashire boiler, the dimensions given in the table above may be reduced by approximately 1½ inches throughout.
f) It is recommended that the breathing space below the furnaces and flues shall be approximately one half the dimensions given in the table above. Whereas it is desired to use any other arrangement which gives a greater or less degree of flexibility, the amount of breathing space shall be specially considered and modified as the necessity of the case requires.
g) For gusset stays above tube nests, as fitted in waste heat boilers without internal furnaces, a breathing space of 8 inches from the centre line of the top tubes to the centre of the toe rivets of the gusset angles is recommended (see Fig. 9).

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
786
PDF page index
786 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 454472b44fc25685
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 482, Regulation 482, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.786. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.