Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 466. Stayed flat surfaces (other than crowns of vertical boilers)
Not yet checked against the official Gazette; verify before relying on it.
466. Stayed flat surfaces (other than crowns of vertical boilers).─ For various braced and stayed flat plates and those which by these regulations require staying as flat surfaces with braces or stay bolts of uniform diameter symmetrically spaced, the thickness shall be calculated by the following formula; namely:-
e = Cd P Equation (12/11)
--- + e1
f1
Where,
P = maximum allowable working pressure in kgf / cm2,
e = thickness, in mm,
d = diameter of the largest circle taken between staying points of the plate (in mm), f1 = 0.85 f (‘f’ as defined in regulation 169), kgf/cm2,
e1= additional thickness equal to 0.75 mm,
C = coefficient having values given in table 12/5below, depending upon the form or method of support adopted.
Original extracted text of the table above, continued (diagnostic)
S. No Table 12/5 Value for ‘C’
| S. No | Component | Value for ‘C’ |
|---|---|---|
| (1) | (2) | (3) |
| 1 | Flanged End Plate | 0.32 |
| 2 | Flat end plates welded to shell from both sides, with following end plate thickness to shell plate thickness ratios ≤ 1.4 > 1.4 ≤ 1.6 > 1.6 ≤ 1.8 > 1.8 ≤ 2.0 | 0.33 0.36 0.39 0.42 |
| 3 | Plain Furnace Less than or equal to 6.5 meters long | 0.3 |
| 4 | Corrugated furnace with corrugation depths ≤ 50 mm | 0.32 |
| 5 | Corrugated furnace with corrugation depths > 50 mm with a length ≤ 6 meter with a length > 6 meter | 0.35 0.37 |
| 6 | Bowling hoop furnace | 0.35 |
| 7 | Access ring welded from both sides | 0.3 |
| 8 | Access ring welded from one side only | 0.45 |
| 9 | Gusset or Link stays | 0.3 |
| 10 | Stay tube in tube nest | 0.39 |
| 11 | Isolated stay tube | 0.45 |
| 12 | Stay bar in group | 0.39 |
| 13 | Isolated stay bar | 0.45 |
Table structure read from the Gazette PDF, pages 778, 779. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
(1) Component (3)
1 0.32
(2)
2 0.33
Flanged End Plate 0.36
0.39
Flat end plates welded to shell from both sides, with following end plate 0.42
thickness to shell plate thickness ratios
≤ 1.4
> 1.4 ≤ 1.6
> 1.6 ≤ 1.8
> 1.8 ≤ 2.0
3 Plain Furnace Less than or equal to 6.5 meters long 0.3
4 Corrugated furnace with corrugation depths ≤ 50 mm 0.32
5 Corrugated furnace with corrugation depths > 50 mm with a length ≤ 6 meter 0.35
with a length > 6 meter 0.37
6 Bowling hoop furnace 0.35
7 Access ring welded from both sides 0.3
8 Access ring welded from one side only 0.45
9 Gusset or Link stays 0.3
10 Stay tube in tube nest 0.39
11 Isolated stay tube 0.45
12 Stay bar in group 0.39
13 Isolated stay bar 0.45Notes: For Flanged end plates, the diameter of largest circle shall be taken from the commencement of the curvature i. of flange.
When largest circle is arrived with different types of supports as mentioned above, average value of ‘C’ shall ii. be taken for calculation.
If the plate is Flame swept, the thickness shall be increased by 10%. iii. The welding material used in the manufacture of these plates shall not have the ultimate tensile strength less iv. than that of the plate used.
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Gives the formula for the thickness of braced and stayed flat plates (other than crowns of vertical boilers) supported by stays of uniform diameter, symmetrically spaced.
Key points
- Thickness e is found from Equation (12/11), using P (pressure, kgf/cm2), d (diameter of the largest circle between staying points, mm), f1 = 0.85 f (f as in regulation 169), an additional thickness e1 of 0.75 mm, and coefficient C.
- Table 12/5 gives C for each form of support: flanged end plates, flat end plates welded from both sides (by end plate to shell plate thickness ratio), plain and corrugated furnaces, bowling hoop furnaces, access rings, gusset or link stays, stay tubes and stay bars. See the Official text tab for values.
Watch out
- For flanged end plates, d is taken from the start of the flange curvature.
- Where the largest circle touches different types of support, use the average value of C.
- If the plate is flame swept, increase the thickness by 10%.
- Welding material must not have a lower ultimate tensile strength than the plate.
- The table layout is broken in the extracted text; check the Gazette page for which C value goes with which row.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 574 | Stayed flat surfaces (other than crowns of Vertical boilers) | 100% | Chapter XII (DPIIT scan), image 6 |
Amendment history of the candidate IBR 1950 regulation: Reg. 574 (1 amendment)
IBR 1950 regulation 574 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 574 page for its amendments.
| Reg. 572, Reg. 573, Reg. 574 | |||||||||||||||||||||||||
Reg. 573 Stand Pipes and branches-
Reg. 574 Stayed Flat surfaces (other than Crowns of Vertical Boilers). Stayed heads/ Braced and stayed surfaces.
| |||||||||||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 466, Regulation 466, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.778–779. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.