BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction

Regulation 483. For boilers as per clause (a)of sub-regulation (9) of regulation 407

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 786–787TableFigure referenced

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

483.For boilers as per clause (a)of sub-regulation (9) of regulation 407.─

(1)Stays shall be arranged to give sufficient breathing space around the furnace connections and tube nests (see figure 12/91 and 12/93), and shall divide the unstayed areas equally.

(2)(a) In case of multi-tubular boilers, for both front and rear attachment of furnaces, the breathing spaces between furnace and tube nests or between furnace and shell shall be minimum of 50 mm or 5% of the shell inside diameter, whichever is larger, with a maximum requirement of 100 mm.

(b)Clearances between the furnace and wet-back wrapper plates shall not require consideration as breathing spaces.

(c)In the case of reverse flame boilers, the breathing space at the front end between furnace and the tube nests shall be not less than 50 mm and the breathing space formed by the outer-annular area of the furnace rear plate shall be not less than 50 mm or 5% of the shell inside diameter, whichever is larger, with a maximum of 100 mm.

(d)Breathing spaces between gusset or link stays and tube ends shall be not less than 100 mm. Clearances between the tubes and wet-back wrapper plates shall not require consideration as breathing spaces.

(e ) Breathing spaces between tubes and shell shall not be less than 40 mm.

(f)Breathing spaces between gusset or link stays and furnaces shall be not less than 200 mm except that for shell outside diameters exceeding 1800 mm and furnace length exceeding 6000 mm they shall be not less than 250 mm and for shell outside diameter less than 1400 mm and furnace lengths less than 3000 mm they shall be not less than 150 mm.

(g)All other breathing spaces shall be a minimum of 50 mm or 3% of the shell inside diameter, whichever is larger, with a maximum requirement of 100 mm.

(3)(a) For Cornish and Lancashire boilers, the circle defining the breathing spaces shall be as shown in

Figure 12/89i.e. the distance ‘AB’ between the centre of the stay circle and the centre of the flue shall be not less than 3e+63, where, ‘e’ is the thickness of the endplate in mm.

Note: For Lancashire boilers, the proportions shown in Table 12/9 given below are recommended for the portion of the end plates above the furnace and flues.

TABLE 12/9: Breathing Space for Lancashire Boilers

Thickness of end plate (in mm)1314161820Over 20
Breathing space (in mm)
(see Figure 12/70)
255280305330330340

Table structure read from the Gazette PDF, page 787. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Thickness of end plate (in mm)                13   14 16 18 20 Over 20
Breathing space (in mm)
(see Figure 12/70)                            255  280 305 330 330 340

(b)It is recommended that the breathing space below the flue be approximately one-half of the dimensions given in Table 12/9.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Referenced provisions

Reg. 407

Figures cited in this regulation (3, exact crops of the Gazette)

Gazette Fig. 12/70: Typical Mild Steel Distance Piece for Mountings
Fig. 12/70Typical Mild Steel Distance Piece for Mountings
View Gazette page 815 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
Gazette Fig. 12/91: Typical Arrangement of End Plates on Economic Boilers
Fig. 12/91Typical Arrangement of End Plates on Economic Boilers
View Gazette page 823 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
Gazette Fig. 12/93: Typical Arrangement of End Plates on Multi-Tubular Boilers
Fig. 12/93Typical Arrangement of End Plates on Multi-Tubular Boilers
View Gazette page 825 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 483 sets the minimum breathing spaces for boilers built under clause (a) of sub-regulation (9) of regulation 407. Stays must leave enough breathing space around furnace connections and tube nests and must divide the unstayed areas equally (Figures 12/91 and 12/93).

Key points

  • (2)(a) Multi-tubular boilers, front and rear furnace attachments: furnace to tube nests, or furnace to shell, at least 50 mm or 5% of the shell inside diameter, whichever is larger. The requirement need not exceed 100 mm.
  • (2)(b) Clearances between the furnace and wet-back wrapper plates are not treated as breathing spaces.
  • (2)(c) Reverse flame boilers: at least 50 mm at the front between furnace and tube nests. The outer annular area of the furnace rear plate needs at least 50 mm or 5% of the shell inside diameter, whichever is larger, with a maximum of 100 mm.
  • (2)(d) Gusset or link stays to tube ends: at least 100 mm. Clearances between tubes and wet-back wrapper plates are not treated as breathing spaces.
  • (2)(e) Tubes to shell: at least 40 mm.
  • (2)(f) Gusset or link stays to furnaces: at least 200 mm. This rises to 250 mm for shell outside diameters over 1800 mm and furnace lengths over 6000 mm. It drops to 150 mm for shell outside diameters under 1400 mm and furnace lengths under 3000 mm.
  • (2)(g) All other breathing spaces: at least 50 mm or 3% of the shell inside diameter, whichever is larger, with a maximum requirement of 100 mm.
  • (3)(a) Cornish and Lancashire boilers: the distance AB between the centre of the stay circle and the centre of the flue must be at least 3e + 63, where e is the end plate thickness in mm (Figure 12/89).
  • Table 12/9 gives recommended breathing spaces for Lancashire boiler end plates above the furnace and flues, by end plate thickness from 13 mm to over 20 mm. Below the flue, about one-half of those values is recommended (3)(b).

Watch out

  • Several limits use "whichever is larger" together with a cap. Check both parts.
  • The Table 12/9 values are recommendations, not minimums. See the Gazette page for the values.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

No candidate heading found in the historical print edition.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
786–787
PDF page index
786–787 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash d4f962c5cfaf612f
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 483, Regulation 483, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.786–787. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.