Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 413. Water-cooled combustion chambers
Not yet checked against the official Gazette; verify before relying on it.
413.Water-cooled combustion chambers.─(1) The attachment of the combustion chambers tube plates and back plates to the wrapper plate shall be in accordance with Figures 12/19, 12/20, 12/21, 12/22 and where the tube plate is flanged for connection to the wrapper plate the weld shall be located between the commencement of curvature of the flange and first row of screwed stays.
(2)The method of attachment of furnace of the flue tubes shall be in accordance with Figures 12/15, 12/16 or 12/17 and access openings shall be in accordance with Figures 12/40 or 12/46.
Figures cited in this regulation (9, exact crops of the Gazette)

View Gazette page 800 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 800 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 801 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 801 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 801 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 801 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 801 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 806 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 808 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 413 covers water-cooled combustion chambers.
Key points
- (1) Tube plates and back plates are attached to the wrapper plate as shown in Figures 12/19, 12/20, 12/21 and 12/22. Where the tube plate is flanged to the wrapper plate, the weld must sit between the start of the flange curvature and the first row of screwed stays.
- (2) Furnace or flue tube attachment, and access openings, follow the figures listed in the regulation.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 413, Regulation 413, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.760. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.