Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 465. Standpipes and branches
Not yet checked against the official Gazette; verify before relying on it.
465.Standpipes and branches.─ (1) The thickness and bolting of all flanges for joining the mountings and fittings shall be in accordance with the dimensions as laid down in Appendix-F to these regulations. In no case, however, shall the thickness of flanges be less than 13 mm. Flanges conforming to International codes and standards such as ASME, BS, EN, DIN can be used meeting required pressure and temperature ratings.
(2)(a) The wall thickness of nozzles and other connections shall not be less than that specified for the applicable loading, namely, internal pressure, bending and static loads.
(b)The pressure loading shall be determined by regulation 455, but in no case shall the thickness be less than that calculated by the following formula:
t = 0.04D + 2.5 mm Equation (12/10)
Where t is the thickness of standpipe and ‘D’ is the outside diameter of connection. If the branch is connected by screwing, the thickness ’t’ shall be measured at the root of the thread.
(3)Where a double flanged steam pipe is tapered, the thickness of flange joining the boiler and fitting shall correspond to the bore of pipe at the flange connection in accordance with Appendix-F to these regulations.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Sets flange and wall thickness rules for standpipes, branches and nozzles that join mountings and fittings.
Key points
- (1) Flange thickness and bolting follow Appendix-F, but no flange may be thinner than 13 mm. Flanges to international codes such as ASME, BS, EN and DIN may be used if they meet the required pressure and temperature ratings.
- (2)(a) Nozzle and connection walls must suit the applicable loading: internal pressure, bending and static loads.
- (2)(b) Pressure loading follows regulation 455, but thickness must never be less than t = 0.04D + 2.5 mm (Equation 12/10), where D is the outside diameter of the connection.
- (2)(b) For screwed branches, t is measured at the root of the thread.
- (3) Where a double flanged steam pipe is tapered, the flange joining the boiler and fitting must correspond to the pipe bore at the flange, per Appendix-F.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 465, Regulation 465, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.777–778. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.