Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 447. Nick-break specimen
Not yet checked against the official Gazette; verify before relying on it.
447.Nick-break specimen .─ (1) This specimen shall have a width not less than one and a half times its thickness and the slot shall be cut in each side of the specimen through the centre of the weld and perpendicular to the outer face of the boiler.
(2)The specimen shall then be broken in the weld and the fracture shall reveal a sound homogenous weld substantially free from slag inclusions, porosity and coarse crystallinity.
In short
Sets how the nick-break specimen is made and what its fracture must show.
Key points
- (1) Width at least one and a half times the specimen thickness. A slot is cut in each side through the centre of the weld, perpendicular to the outer face of the boiler.
- (2) The specimen is broken in the weld. The fracture must show a sound, homogeneous weld substantially free from slag inclusions, porosity and coarse crystallinity.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 420 | Nick Break Test | 80% | Chapter X (DPIIT scan), image 7 |
IBR 1950 regulation 420 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 420 page for its amendments.
| Reg. 420, Reg. 421, Reg. 422, Reg. 423
Reg. 421
Reg. 422
Reg. 423
|
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 447, Regulation 447, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.771. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.