Regulation 405. Circularity
Not yet checked against the official Gazette; verify before relying on it.
405. Circularity. ─ (1) The difference between the maximum and minimum internal diameters of the shell measured at any one cross section shall not exceed one per cent of the nominal internal diameter.
(2)The profile as measured on the outside of the boiler by means of a gauge of the designed form of the exterior of the boiler, having a length equal to one quarter of the internal diameter, shall not depart from the designed form by more than the percentage given in Table 12/1.
TABLE 12/1: Maximum percentage departure from designed form of welded boilers
| Serial Number | Nominal internal diameter of boiler ‘D’ in mm | Maximum departure from designed form in percentage |
|---|---|---|
| (1) | (2) | (3) |
| 1. | Up to and including 915 | 0.375 |
| 2. | Over 915, up to and including 1150 | 0.350 |
| 3. | Over 1150 | 0.300 |
Table structure read from the Gazette PDF, page 757. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Serial Nominal internal diameter of boiler ‘D’ Maximum departure from designed form Number in mm in percentage (1) (2) (3) 1. Up to and including 915 0.375 2. Over 915, up to and including 1150 0.350 3. Over 1150 0.300
(3)There shall be no flats at the welded seams and any local departure from circularity shall be gradual.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 405 sets how round the shell of a welded boiler must be.
Key points
- (1) At any one cross section, the difference between the maximum and minimum internal diameters must not exceed one per cent of the nominal internal diameter.
- (2) The outside profile is checked with a gauge of the designed form, one quarter of the internal diameter long. Departure from the designed form must not exceed Table 12/1:
- up to and including 915 mm: 0.375 per cent;
- over 915, up to and including 1150 mm: 0.350 per cent;
- over 1150 mm: 0.300 per cent.
Watch out
- (3) No flats are allowed at the welded seams, and any local departure from circularity must be gradual.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 405, Regulation 405, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.757. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.