Indian Boiler Regulations, 2026 · Chapter 12 · Shell Type Boilers of Welded Construction
Regulation 494. Circular reversal chambers
Not yet checked against the official Gazette; verify before relying on it.
494. Circular reversal chambers. ─ (1) (a) The thickness of wrapper plates of cylindrical reversal chambers of horizontal multi-tubular boilers shall be calculated in accordance with the equations given in regulation 488. The thickness shall be not greater than 35 mm and shall be not less than 10 mm.
(b)However, the design temperature for reversal chamber wrapper plates shall be determined in accordance with the following equations: -
t = (ts + 2e2) or (ts + 50) whichever is greater.
Where, t = Design temperature (in degree centigrade)
ts = Saturation temperature of water (in degree centigrade) at the maximum allowable working pressure, for both steam or hot water boilers.
e2 = nominal plate thickness (in mm).
(2)(a) The thickness of access tubes shall be calculated in accordance with regulation 488 with a minimum thickness of 10 mm.
(b)However, the design temperature for access tubes shall be determined in accordance with the following equations: -
t = (ts + 2e2) or
(ts + 50) whichever is greater.
Where, t = Design temperature (in degree centigrade)
ts = Saturation temperature of water (in degree centigrade) at the maximum allowable working pressure, for both steam or hot water boilers.
e2 = nominal plate thickness (in mm).
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 494 covers cylindrical reversal chambers of horizontal multi-tubular boilers and their access tubes. Both are sized with the equations in regulation 488, but with their own design temperature.
Key points
- (1)(a) Wrapper plates: thickness not greater than 35 mm and not less than 10 mm.
- (2)(a) Access tubes: minimum thickness 10 mm.
- (1)(b) and (2)(b) Design temperature t is the greater of (ts + 2e2) and (ts + 50), where:
- ts is the saturation temperature of water at the maximum allowable working pressure (°C);
- e2 is the nominal plate thickness (mm).
- The design temperature rule applies to both steam and hot water boilers.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 494, Regulation 494, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.793–794. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.