Regulation 420. Manhole frames, mouthpieces and doors
Not yet checked against the official Gazette; verify before relying on it.
420. Manhole frames, mouthpieces and doors.─ (1) Manhole frames, mouth-pieces, doors or cover plates shall be of mild steel. Frames shall be oval and where of the flanged type, shall be formed to bed closely to the shell and provide a flat joining surface to the door. Alternatively, raised circular mouth-pieces may be fitted externally and where of the flanged type shall be bedded closely to the shell.
(2)Wherever practicable, the frame shall be attached to the inside of the shell with the shorter axis parallel to the longitudinal centre line of the boiler. In all cases where the shell thickness exceeds 14 mm, oval frames or circular mouth-pieces shall be fitted.
(3)Oval frames and externally raised circular mouthpieces shall be either:
(a)Formed in one piece without weld, or
(b)Formed from a suitable rolled section and forge-welded, or fabricated by fusion welding, provided they are stress-relieved by heat-treatment after welding and before attaching to the boiler unless the whole boiler is to be subjected to heat-treatment on completion.
(4)Welds shall be positioned so that they are located on the transverse centre line of the boiler (see regulation 430).
(5)The joining flanges of mouthpieces and covers shall be machined on the face and edges and on the bearing surface for the bolts. Bolts and nuts shall be machined where in contact with the flanges and the joints shall be formed inside and outside the pitch line or pitch circle of the bolts to preclude the possibility of flange distortion. Cover plates shall be dished outwards to a depth of approximately one-eighth of the internal diameter of the frame.
(6)All edges shall be machined or flame-cut by machine (see regulation 402).
(7)Forms of manhole frames and attachments are shown in Figures 12/65, 12/66, 12/67, 12/68 and 12/69. For Manhole, head hole or access opening connections, where compensation calculation performed as per regulation 463, does not require compensating plates, Figure 12/108 to be used for attachment to shell.
Figures cited in this regulation (5, exact crops of the Gazette)

View Gazette page 813 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 813 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 814 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 814 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)

View Gazette page 815 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 420 sets material, form and fitting rules for manhole frames, mouthpieces, doors and cover plates.
Key points
- (1) All must be mild steel. Frames are oval; flanged frames must bed closely to the shell and give a flat joint face for the door. Raised circular mouthpieces may instead be fitted externally.
- (2) Where practicable, the frame is attached inside the shell with its shorter axis parallel to the boiler's longitudinal centre line.
- (3) Oval frames and raised circular mouthpieces are (a) one piece without weld, or (b) from a rolled section forge-welded, or fabricated by fusion welding, then stress-relieved before attachment unless the whole boiler is heat-treated on completion.
- (4) Welds lie on the boiler's transverse centre line (see regulation 430).
- (5) Joint flanges are machined on face, edges and bolt bearing surface; bolts and nuts are machined where they touch the flanges. Joints are formed inside and outside the bolt pitch line to prevent flange distortion. Cover plates are dished outwards to about one-eighth of the frame's internal diameter.
- (6) All edges are machined or machine flame-cut (see regulation 402).
- (7) Frame forms and attachments are shown in the listed figures. Where compensation calculated under regulation 463 needs no compensating plates, Figure 12/108 is used for the shell attachment.
Watch out
- (2) Where the shell is thicker than 14 mm, oval frames or circular mouthpieces must be fitted in all cases.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 420, Regulation 420, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.762–763. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.