Reg. 594 Corrugated Fireboxes of Vertical Boilers
Reg. 595
| |||||||||||||||
Earlier text: the 2008 DIPP web edition
Corrugated Fireboxes of Vertical Boilers
For the semi-spirally corrugated fireboxes of ‘Sentinel’ standard motor wagon boilers the working pressure shall be determined by the following formula-
C(t-1)
W.P. = Equation XII/29
D
W.P. is working pressure in pounds per square inch. t is thickness of the firebox plate in thirty seconds of an inch.
D is mean of the external diameters of firebox measured over the plain part at each end at commencement of curvature of flange.
C = 390.