Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 595 — Hemispherical Furnaces of Vertical Boilers
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 593, 594. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 593, Reg. 594, Reg. 595 | |||||||||||||||
Reg. 594 Corrugated Fireboxes of Vertical Boilers
Reg. 595
| |||||||||||||||
Earlier text: the 2008 DIPP web edition
Hemispherical Furnaces of Vertical Boilers
When furnaces are hemispherical in form and subject to pressure on the convex side and are without support from stays of any kind the maximum working pressure shall be found by the following formula:-
275(t-1)
W.P. = Equation XII/30
R
W.P. is working pressure in pounds per square inch. t is thickness of the top plate in thirty seconds of an inch.
R is outer radius of curvature of the furnace in inches.
The thickness of these furnaces shall in no case exceed 7/8 inch