Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 593 — Plain Furnaces of Vertical Boilers
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 594, 595. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 593, Reg. 594, Reg. 595 | |||||||||||||||
Reg. 594 Corrugated Fireboxes of Vertical Boilers
Reg. 595
| |||||||||||||||
Earlier text: the 2008 DIPP web edition
Plain Furnaces of Vertical Boilers
The maximum working pressure of Plain Furnaces of Vertical boilers shall be the lesser of the two values obtained by Equations XII/25 and XII/26.
Where,
D = external diameter of the firebox in inches. Where the firebox is tapered the diameter taken shall be the mean of that at the top and at the bottom where it meets the substantial support from the flange or ring.
L is length of the firebox in inches between points of substantial support measured from the commencement of flange curvature or from the foundation connection, or from a row of screwed stays which comply with Regulations 550(b), 585(b), whichever is applicable.
In no case, however, shall the thickness be more than 7/8 inch. For fireboxes under 2 feet and 6 inches in diameter, the thickness shall be not less than 5/16 inch and for fireboxes 2 feet and 6 inches in diameter and over the thickness shall be not less than 3/8 inch.