Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 596 — Foundations of Vertical Boilers Furnaces
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 597. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 596, Reg. 597 | ||||||||||||||||||
Reg. 597 Foundations of Loco-type Boiler Fireboxes
| ||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Foundations of Vertical Boilers Furnaces
When circular furnaces of fireboxes of vertical boilers are not connected to the shell crown by uptake tube, smoke tubes or bolt stays and the whole load on the firebox vertically is borne by the bottom part of the firebox where it is connected to the shell the working pressure for the part, if firebox is joggled out to meet the shell or if any ogee ring is fitted, shall not exceed that found by the following formula:-
C(t-1)²
W.P. = Equation XII/31
D(D-D1)
W.P. is working pressure in pounds per square inch. t is thickness of the joggled firebox plate or ogee ring in thirty seconds of an inch. D is inside diameter of the boiler shell in inches.
D1 is outside diameter of the joggled firebox at the commencement of curvature Above joggled part or the outside diameter of the firebox where it joins the ogee ring.
C = 140 for Ogee rings (see Fig XII/26 and XII/27.
C = 100 where ‘U’ ring section is used (see Fig. XII/28)
Possible IBR 2026 successors (heading match, unverified): Reg. 96, Reg. 410, Reg. 495, Reg. 496, Reg. 497, Reg. 498, Reg. 499