Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 597 — Foundations of Loco-type Boiler Fireboxes
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 596. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 596, Reg. 597 | ||||||||||||||||||
Reg. 597 Foundations of Loco-type Boiler Fireboxes
| ||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Foundations of Loco-type Boiler Fireboxes
Where the firebox roof in loco-type boilers is, not stayed direct to the external casing crown or to girders carried by the casing or if not connected to the casing by slings the working pressure for the parts, if plates are joggled out to meet the casing or if an ogee ring is fitted, shall not exceed that found by the following formula:-
(t-1) x (L+W)
W.P. = 70 Equation XII/32
L+W(W-W1)
WP is working pressure in pounds per square inch. t is thickness of the joggled firebox side plates or fire hole plate (whichever is less) or ogee ring in thirty seconds of an inch.
L is length of firebox casing in inches measured between the water sides of front end plate and saddle plate at the foundation seam.
W is width of firebox casing in inches measured between the water side of casing side plates at the foundation seam.
W1 is width of firebox in inches measured between the water sides of firebox side plates at the commencement of curvature above joggled part or where it joins the ogee ring.
Where only a comparatively narrow strip of the firebox roof is stayed directly to the casing crown the area so stayed shall be deducted from the area represented by LXW in the bottom line of the formula thus:
(L X W – A)(W-W1) and so used in Equation XII/32 in determining the working pressure for the parts, “A” being the area in square inches of the part of roof supported by the casing crown.