Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 568 — Dished ends subject to external pressure
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 569, 570. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 568, Reg. 569, Reg. 570 | |||||||||
Reg. 569 Hemispherical crowns
Reg. 570 Manholes and other openings in shells
| |||||||||
Earlier text: the 2008 DIPP web edition
Dished ends subject to external pressure
In the case of unstayed dished ends for the coefficient 15 in Equation XII/7, the coefficient 12 shall be substituted, and R shall be the outer radius of the curvature of plate, which shall not exceed the external diameter of the shell to which it is attached.
For plates exposed to furnace-flame the coefficient shall be 10.5. In no case shall R/t exceed 2.75.
The inside radius of curvature at the flange shall be not less than 4 times the thickness of the end plate and in no case less than 2 ½ inches.
The inside radius of the curvature of the flange to uptake shall be not less than twice the thickness of the crown plate and in no case less than one inch.
Possible IBR 2026 successors (heading match, unverified): Reg. 116, Reg. 458, Reg. 460