Indian Boiler Regulations, 2026 · Chapter 3 · Construction and Workmanship

Regulation 95. Furnaces of horizontal boilers

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 563–564

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

95. Furnaces of horizontal boilers.─ (1) The sections of the internal flues shall each be in one plate and shall be bent while cold to circular form and shall be welded longitudinally.

(2)The maximum permissible variation in diameter at any cross-section shall not exceed the thickness of the plate.

(3)The weld shall be placed at the lower part of the flues, and shall break joint in successive sections by at least 305 mm.

(4)Each flange for the circular seams shall be formed at one heat by suitable machinery.

(5)The sections shall be allowed to cool gradually to avoid internal stresses.

(6)The caulking edges of all flue flanges shall be machined or machine gas cut.

(7)The circular seams shall be arranged so that they do not fall in line with those of the adjacent flue or with the circumferential seams of the shell and are at least 152 mm apart.

(8)When flues are flanged for attachment to both end plates the total length of each completed flue shall not exceed the length of the shell measured from the inner surface of the back end plate to the inner surface of the front end plate, both adjacent to the shell.

(9)Where the flues are flanged for attachment to the end plates, the end sections shall be 1.5 mm thicker than the remaining sections, except in cases where the calculated thickness is over 21 mm, when the end section shall be 22 mm in thickness.

(10)The flanged portion of furnace rings shall have radius of curvature of not less than 25 mm on water side.

(11)Sections of corrugated flues may be fusion butt welded circumferentially and afterwards stress relieved by heat treatment.

(12)As an alternative to adamson flanges, furnaces which are partly fitted with corrugated sections shall be strengthened by means of suitable stiffening rings adequately welded to the furnaces. In no case shall a flat stiffener be less than 63 mm x 13 mm.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 95 sets construction rules for the internal flues (furnaces) of horizontal boilers.

Key points

  • (1) Each flue section is one plate, bent cold to circular form and welded longitudinally.
  • (2) Variation in diameter at any cross-section must not exceed the plate thickness.
  • (3) The longitudinal weld is at the lower part of the flue and breaks joint in successive sections by at least 305 mm.
  • (4), (5), (6) Each circular seam flange is formed at one heat by machine. Sections cool gradually. Caulking edges of flue flanges are machined or machine gas cut.
  • (7) Circular seams must not line up with those of an adjacent flue or with the shell's circumferential seams, and must be at least 152 mm apart.
  • (8) Where flues are flanged to both end plates, the completed flue length must not exceed the shell length between the inner surfaces of the end plates.
  • (9) Where flues are flanged to end plates, the end sections are 1.5 mm thicker than the rest. Where the calculated thickness is over 21 mm, the end section is 22 mm.
  • (10) The flanged part of furnace rings has a radius of at least 25 mm on the water side.
  • (11) Corrugated flue sections may be fusion butt welded circumferentially and then stress relieved.
  • (12) Instead of Adamson flanges, partly corrugated furnaces may use welded stiffening rings. A flat stiffener must be at least 63 mm x 13 mm.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
122Furnaces of Horizontal Boilers100%Chapter III (DPIIT scan), image 3
221Corrugated Furnaces of Horizontal Boilers100%Chapter IV (DPIIT scan), image 14
592Furnaces and Flue Sections of Horizontal Boilers100%Chapter XII (DPIIT scan), image 13

Amendment history of the candidate IBR 1950 regulations: Reg. 592 (6 amendments)

IBR 1950 regulation 122 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 122 page for its amendments.

Reg. 122
FURNACES
Furnaces of Horizontal boilers

a) The sections of the internal flues shall each be in one plate and shall be bent while cold to circular form and shall be welded longitudinally.
b) The maximum permissible variation in diameter at any cross section shall not exceed the thickness of the plate.
c) The weld shall be placed at the lower part of the flues, and shall break joint in successive sections by at least 12 inches.
d) Each flange for the circular seams shall be formed at one heat by suitable machinery.
e) The sections shall be allowed to cool gradually to avoid internal stresses.
f) The caulking edges of all flue flanges shall be machined or machine gas cut.
g The circular seams shall be arranged so that they do not fall in line with those of the adjacent flue or with the circumferential seams of the shell and are at least 6 inches apart.
h) When flues are flanged for attachment to both end plates the total length of each completed flue shall not exceed the length of the shell measured from the inner surface of the back end plate to the inner surface of the front end plate, both adjacent to the shell.
i) Where the flues are flanged for attachment to the end plates, the end sections shall be 1/16 inch thicker than the remaining sections, except in cases where the calculated thickness is over 13/16 inch, when the end section shall be 7/8 inch in thickness.
j) The flanged portion of furnace rings shall have radius of curvature of not less than 1 inch on water side.
k) Sections of corrugated flues may be fusion butt welded circumferentially and afterwards stress relieved by heat treatment.
l) As an alternative to Adamson flanges, furnaces which are partly fitted with corrugated sections shall be strengthened by means of suitable stiffening rings adequately welded to the furnaces. The moment of inertia of the stiffener shall be not less than that required by Regulation 592(b). In no case shall a flat stiffener be less than 63 mm. x 13 mm. (2½” x ½”).

IBR 1950 regulation 221 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 221 page for its amendments.

Reg. 220, Reg. 221, Reg. 222

FURNACES

Plain Furnaces of Horizontal Boilers

For plain furnaces or furnaces strengthened by Adamson or other joints or stiffeners of sufficient strength and for the semi-cylindrical tops of fire-boxes and bottom of combustion chambers where the sides are securely stayed, the working pressure shall not exceed the smaller of the values obtained from the following formulae :-
W. P. = C X (t - 1)2 Eqn.(57)
D ( L + 24 )

W. P. = C1 X {10 ( t - 1) - L ) Eqn.(58)
D

Where
d = the external diameter of the furnace or chamber top or bottom in inches

t = the thickness of the furnace plate in 32nds of an inch.

L = the length of the furnace or other part in inches measured between points of substantial support, i.e. centres of rows of rivets in end seams or commencement of curvature of flange, whichever is applicable.

C = 1450 where the longitudinal seams of steel furnaces are welded and 1300 where they are riveted,

C = 725 where the longitudinal seams of circular copper fireboxes or furnaces are fitted with double butt straps and 650 where they are lapped,

C1 = 50 where the longitudinal seams of steel furnaces are welded and 45 where they are riveted,

C1 = 25 where the longitudinal seams of circular copper fireboxes or furnaces are fitted with double butt straps and 22.5 where they are lapped.

Reg. 221

FURNACES

Corrugated Furnaces of Horizontal Boilers

The maximum working pressure to be allowed on corrugated furnaces shall be determined by the following formula -
W. P. = C ( t - 1 ) Eqn.(59)
D

where
D is the least external diameter in inches measured at the bottom of the corrugations on the water side.

t is the thickness of the furnace plate in 32nds of an inch measured at the bottom of the corrugation or chamber,

C = 480 for the Fox, Morrison, Deighton, Purves,, and other similar furnaces and 510 for the leeds Forge Bulb Suspension Furnace.

Reg. 222

FURNACES

Plain Furnaces of Vertical Boilers

The same formulae as for the plain furnaces of horizontal boilers shall be used, but where the furnaces are tapered the diameter to be taken for calculation purposes shall be the mean of that at the top and of that at the bottom where it meets the substantial support from flange or ring. The length for the same purpose shall be the distance from the centre of the row of rivets connecting the crown and the body of the furnace to the substantial support at the bottom of the furnace, or to a row of screwed stays connecting the furnace to the shell, provided that the pitch of stays at the furnace does not exceed 14 times the thickness of the furnace plate when the stays are riveted at their ends or 16 times when the stays are fitted with nuts. Such screwed stays shall be in diameter over the threads not less than twice the thickness of the furnace plate and in no case less than 3/4" diameter {See Reg.135 (d)}.
IBR 1950 regulation 592 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 592 page for its amendments.

Reg. 592

Furnaces, furnaces components, wet back reversal chambers and fire boxes of cylindrical form subject to external pressure.-

Furnaces:

a) Maximum furnace diameter. The mean diameter of furnaces shall not exceed 1800 mm.
b) Notations:

b - is the pitch of the furnace corrugations (in mm);

c - is the corrosion allowance = 0.75mm

d - is the mean diameter of furnace (in mm) (see note 1);

dmax - is the maximum mean diameter of the furnace (in mm)

dmin - is the minimum mean diameter of the furnace (in mm);

e - is the furnace plate thickness (in mm);
E - is Young’s modulus of elasticity (in kg/cm²) at the design temperature.
Et - is the specified minimum elevated temperature yield stress or the 0.2% proof stress at the design temperature (in kg/cm²);
F - is the cross-sectional area of a longitudinal section of the corrugated furnace wall, of length b and thickness (e-c) (in mm²) (see Figs. XII/94A to C, XII/94D to E, XII/94F to G).

I - is the second moment of area of one complete corrugation about its neutral axis excluding the corrosion allowance (in mm4);
Is - is the second moment of area of plain stiffener section(see Fig. XII/21 & XII/22) about its neutral axis, including a length of the furnace of 0.55 (de)1/2 on each side of the stiffener (in mm4) (see note 2);
L - is the distance between the centre of two effective points of support (in mm) (see note 3);
P - Is the design pressure (in kg/cm²)
S1 - is the factor of safety:
     =2.5 for furnaces in class I and class II boilers
    =3.5 for furnaces in class III boilers
    =2.0 for furnaces and wrapper plates not exposed to flame.
S2 - is the factor of safety:
    =3.0 for class I and class II boilers
    =3.9 for class III boilers
u - is the percentage out of roundness to be taken as 1.5 for plain furnaces      and1.0 for corrugated furnaces;
w - is the depth of corrugation (in mm).

NOTE 1: For corrugated furnaces, mean diameter is equal to inside diameter plus full depth of one corrugation referred to in Fig. XII/94  which is equal to the inside diameter + e + W.

NOTE 2: When calculating Is, it is only necessary to take into account a corrosion allowance on the furnace gas side.

NOTE 3: Stiffeners complying with figure XII/21 and XII/22 boiler and reversal chamber end plates are considered to be effective points of support.

NOTE 4: The design temperature of the furnace = ts +4e + 15 saturation temperature plus four times the thickness of the furnace plus 15.

Next >>>

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
563–564
PDF page index
563–564 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 46fb61a8e79b3014
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 95, Regulation 95, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.563–564. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.