Regulation 87. Strengthening of flat end plate at manhole

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 562

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

87. Strengthening of flat end plate at manhole.─ (1) In all cases, the front end plate gusset stays below the furnaces shall be placed as closely as possible to the mudhole frame.

(2)Where flat end plates are flanged for connection to the shell, the inside radius of flanging shall be not less than 1.75 times the plate thickness, with a minimum of 38 mm.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 87 covers two details of flat end plates: placing gusset stays near the mudhole frame, and the minimum flanging radius.

Key points

  • (1) Front end plate gusset stays below the furnaces are placed as close as possible to the mudhole frame.
  • (2) Where flat end plates are flanged to connect to the shell, the inside flanging radius must be at least 1.75 times the plate thickness, with a minimum of 38 mm.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
114Stren thening of Flat End Plate at Manhole98%Chapter III (DPIIT scan), image 2
157Plate les,71%Chapter III (DPIIT scan), image 10
589Flat Plate Margins71%Chapter XII (DPIIT scan), image 11
IBR 1950 regulation 114 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 114 page for its amendments.

Reg. 114
END PLATES
Strengthening of Flat End Plate at Manhole

a) In the End Plates of Lancashire Boiler type, the mudhole in the lower part of the front end plate shall be fitted with a flanged riveted strengthening ring, the thickness of the flat portion of which shall be not less than (1.5T + 1/8 inch) where T equals the thickness of the end plate in inches.
b) In boilers 7 ft. 6 inches diameter and above, the mudhole frame shall be fitted with a peak to reinforce the portion of the end plate between and below the furnaces, and this peak shall be securely riveted thereto with rivets of similar pitch to the remainder of the frame.
c) In all cases the front end plate gusset stays below the furnaces shall be placed as closely as possible to the mudhole frame.
d) Where flat end plates are flanged for connection to the shell, the inside radius of flanging shall be not less than 1.75 times the plate thickness, with a minimum of 1½ inches.

IBR 1950 regulation 157 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 157 page for its amendments.

Reg. 157
STAND PIPES, PADS ETC.

Pressed Plate Saddles

Where pressed plate saddles are employed they shall be formed to bed closely to the boiler, and machined on the face jointing the mounting and on the edges. The studs for attachment of mountings if screwed through the saddle, shall each be fitted with a nut on the inside having a thickness equal to the diameter of the stud. Where the stud holes do not penetrate through the saddle, the length of the screwed portion of the stud in the plate shall not be less than the diameter of the stud.

IBR 1950 regulation 589 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 589 page for its amendments.

Reg. 589

Flat Plate Margins

The amount of support in relief of the stays which may be attributed to the shell, furnaces or flues to which flat plates are attached, shall not exceed that determined by the following formulae:-


Width of margin in inches = 
C(t-1) Equation XII/23
Ö   W.P.

t is plate thickness in thirty seconds of an inch.
W.P. is working pressure in pounds per square inch.
C=3.47 for plates exposed to flame.
C=3.70 for plates not exposed to flame.

Where the plates are flanged, the margin shall be measured from the commencement of curvature of flanging, or from a line 3 ½ times the thickness of the plate measured from the outside of the plate, whichever is nearer to the flange. Where the flat plate is not flanged for attachment to the shell or flue tubes and is welded as shown in figure XII/12 or XII/16 the width of the margin shall be measured from the inside of the shell or the outside of the flue tube, whichever is applicable.

In no case, however, shall the diameter D of the circle forming the boundary of the margin supported by the uptake of a vertical boiler be greater than that found by the following formula:-

           _____
D =   / 5000A       Ö   ------------ + d²               W.P
Equation XII/24

A is cross sectional area of the uptake tube in square inches,
W.P. is working pressure in pounds per square inch,
d is external diameter of uptake in inches.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
562
PDF page index
562 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 1a6e2a42ff63ed72
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 87, Regulation 87, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.562. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.