Regulation 102. Bar stays

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 566

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

102. Bar stays.─ Bar stays shall not be welded at any part. They shall preferably have plus threads and the ends of the stays being upset or the middle portion being reduced for this purpose. Stay bars which have been worked in the fire shall be subsequently annealed.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 102 says bar stays should preferably have "plus threads" (term as printed in the Gazette), made by upsetting the ends or reducing the middle portion. Stay bars worked in the fire must be annealed afterwards.

Watch out

  • Bar stays must not be welded at any part.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
134Diagonal Bar or Rod Stays100%Chapter III (DPIIT scan), image 6
588Loads on Stay Tubes and Bar Stays100%Chapter XII (DPIIT scan), image 11
30Stay Bars89%Chapter II (DPIIT scan), image 3
IBR 1950 regulation 134 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 134 page for its amendments.

Reg. 133, Reg. 134
STAYS
Jointed Stays

Where jointed longitudinal stays are fitted, they shall, where practicable, be fitted with pins having an effective sectional area 25 per cent in excess of that of the stay. If the pins are slack in the holes, the total slackness shall not be more than 1/6 inch. The pins shall be as close as possible to the shoulder of the eye forging. The shoulder of the forging shall be at least ½ inch wide all round, i.e., the diameter at the shoulder shall be not less than the diameter of the hole plus 1 inch .

Reg. 134
STAYS
Diagonal Bar or Rod Stays

The sectional area of diagonal rod or bar stay shall bear the same proportion to that of a direct stay as the length of the diagonal stay bears to the length of the perpendicular line from the end of the diagonal stay to the surface supported. The ends of diagonal stays, shall not be bent, but shall be attached to the plate with revelled washers and nuts or with riveted tee, blocks or angles and shackle pins (see Regulation 133 for eyes and pins).
IBR 1950 regulation 588 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 588 page for its amendments.

Reg. 587, Reg. 588

Longitudinal Bar Stays

The maximum working pressure for longitudinal bar stays is to be calculated from the appropriate one of the following two formulae:

WP= C         1.28
(D - ------------)²
        N
Equation XII/21
A

WP= C x D1² Equation XII/22
A

WP is working pressure in pounds per square inch,
D is diameter of stays over threads in inches,
D1 is diameter of body of stays at its smallest part in inches,
N is the number of threads of stay per inch,
A is area in square inches supported by one stay.
C is values given in Table below:

TABLE XII/5
Stress on Longitudinal Bar Stays
Range of tensile strength of bar
Value of C
Tons per square inch Pounds per square inch
26/30 7850
28/32 8640
30/34 9420
32/36 10200

Where bar stays are fitted in vertical boilers, not less than four bar stays shall be fitted to boilers of 4 feet and over but under 5 feet in diameter; five bar stays to boilers of 5 feet and over but under 6 feet in diameter; six bar stays to boiler of 6 feet and over in diameter.

In no case, shall the diameter of the stay at any part be less than 1 inch. Where joined stays are fitted, the strength of the knuckle joint employed shall be at least equal to the strength of the remainder of the bar stay.


Reg. 588

Loads on Stay Tubes and Bar Stays

Stay tubes and bar stays shall be designed to carry the whole load due to the pressure on the area to be supported, the areas being calculated as follows:-

a) For a stay tube within the tube nest the net area to be supported shall be the product of the horizontal and vertical pitches, in inches, of the stay tubes less the area of the tube holes embraced. Where the pitch of the stay tubes is irregular the area shall be taken as the square of the mean pitch of the stay tubes (i.e., the square of ¼ of the sum of the four sides, of any quadrilateral bounded by four adjacent stay tubes), less the area of the tube holes embraced.
b) For a stay tube in the boundary row, or for a bar stay, the net area to be supported shall be the area, in square inches enclosed by lines passing midway between the stay and the adjacent points of support and by the boundary margin (see Regulation 589), less the area of any tubes or stays embraced.
c) In the case of a bar stay where there are no stay tubes in the tube nest the area to be supported shall extend to the tangential boundary of the tube nest.
IBR 1950 regulation 30 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 30 page for its amendments.

Reg. 30
MATERIALS OF CONSTRUCTION

WROUGHT IRON STAY AND RIVET BARS

Stay Bars

The tensile breaking strength shall be between 21 and 25 tons with an elongation of not less than 22 per cent measured on the Standard Test Piece B or 27 per cent measured on the Standard Test Piece B1.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
566
PDF page index
566 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash e309e72bea50aaa7
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 102, Regulation 102, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.566. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.