Indian Boiler Regulations, 2026 · Chapter 3 · Construction and Workmanship

Regulation 107. Screwed stays

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 567

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

107. Screwed stays.─ (1) Screwed stays and the holes for these shall be screwed with a continuous thread.

(2)The screwed threads of the stay shall be clean and free from checks or imperfections, of full depth, correct whitworth form and a good fit in the holes. The middle portion shall preferably be turned down to the bottom of the thread.

(3)The stays shall be screwed with fine threads of not less than 11 threads per 25 mm.

(4)The diameter of the stay over the threads shall not be less than 19 mm or twice the thickness of the firebox plate whichever is the greater.

(5)The pitch of the stays at the furnace of vertical boilers shall not exceed 14 times the thickness of the furnace plate.

(6)Where the stays are not fitted with nuts, the ends shall be riveted over to form substantial heads. Alternatively stays may be screwed through the shell and firebox plates and the projecting ends shall be substantially fillet welded in an approved manner. The projection of the end of the stay from the surface of the plate shall be not less than one quarter of the diameter of the stay but in no case less than 6 mm. The full end of the stay shall be visible on completion of the welding.

(7)Crown stays of Loco type boilers shall either be fitted with nuts or riveted over on the fire side.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 107 sets thread, size, pitch and end-finish rules for screwed stays.

Key points

  • (1), (2) Stays and their holes have a continuous thread that is clean, full depth, correct Whitworth form and a good fit. The middle portion is preferably turned down to the bottom of the thread.
  • (3) Fine threads of not less than 11 threads per 25 mm.
  • (4) Diameter over the threads is at least 19 mm or twice the firebox plate thickness, whichever is greater.
  • (5) At the furnace of vertical boilers, stay pitch must not exceed 14 times the furnace plate thickness.
  • (6) Stays without nuts are riveted over to form substantial heads. Alternatively, they may be screwed through both plates and the projecting ends fillet welded in an approved manner. The projection is at least one quarter of the stay diameter, and never less than 6 mm. The full stay end must remain visible after welding.
  • (7) Crown stays of loco type boilers are fitted with nuts or riveted over on the fire side.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
135Screwed Stays100%Chapter III (DPIIT scan), image 6

Amendment history of the candidate IBR 1950 regulation: Reg. 135 (1 amendment)

IBR 1950 regulation 135 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 135 page for its amendments.

Reg. 135
SCREWED STAYS
Screwed Stays

a) Screwed stays and the holes for these shall be screwed with a continuous thread.
b) The screwed threads of the stay shall be clean free from checks or imperfections, of full depth, correct Whitworth form and a good fit in the holes. The middle portion shall preferably be turned down to the bottom of the thread.
c) The stays shall be screwed with fine threads of not less than 11 threads per inch.
d) The diameter of the stay over the threads shall not be less than ¾ inch or twice

the thickness of the firebox plate whichever is the greater.
e) The pitch of the stays at the furnace of vertical boilers shall not exceed 14 times the thickness of the furnace plate.
f) Where the stays are not fitted with nuts, the ends shall be riveted over to form substantial heads.

Alternatively stays may be screwed through the shell and firebox plates and the projecting ends shall be substantially fillet welded in an approved manner. The projection of the end of the stay from the surface of the plate shall be not less than one quarter of the diameter of the stay but in no case less than ¼ inch. The full end of the stay shall be visible on completion of the welding.
g) Crown stays of Loco type boilers shall either be fitted with nuts or riveted over on the fire side.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
567
PDF page index
567 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 88f91613e6ae4a9c
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 107, Regulation 107, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.567. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.