Indian Boiler Regulations, 2026 · Chapter 3 · Construction and Workmanship
Regulation 127. Design of stand pipes
Not yet checked against the official Gazette; verify before relying on it.
127. Design of stand pipes.─ The design of the branches and stand-pipe shall be regulated in the following manner:
(i)in order to withstand the maximum allowable working pressure, the minimum thickness of branch and stand-pipe shall be determined in accordance with the provisions specified in sub-regulation (1) of regulation 244;
(ii)Compensation requirements for openings in the main pressure parts shall be determined in accordance with the provisions of regulation 179;
(iii)The additional thickness shall be considered to withstand superimposed loading due to connecting pipe-work or fittings.
(iv)The minimum thickness of the branch or standpipe shall be the greatest of the values required above and shall not be less than 0.015 do plus 3.2 mm where, do is the outside diameter of the branch (in mm);
Provided that the provisions of the regulations shall not apply to such tube stub which have been designated as tubes.
In short
Regulation 127 sets how to find the minimum thickness of branches and stand pipes.
Key points
- (i) Thickness for the maximum allowable working pressure is found by sub-regulation (1) of regulation 244.
- (ii) Compensation for openings in main pressure parts follows regulation 179.
- (iii) Extra thickness must be allowed for superimposed loads from connected pipework or fittings.
- (iv) The minimum thickness is the greatest of these values, and never less than 0.015 do plus 3.2 mm, where do is the branch outside diameter in mm.
Watch out
- The regulation does not apply to tube stubs that have been designated as tubes.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 127, Regulation 127, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.580–581. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.