Indian Boiler Regulations, 2026 · Chapter 3 · Construction and Workmanship

Regulation 114. Gusset angles

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 570

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

114. Gusset angles.─ The gusset angles connecting the stays to the shell and end plates shall be at least 7/8th of the thickness of the shell plate, but shall be not less than 13 mm thickness.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 114 says gusset angles connecting the stays to the shell and end plates must be at least 7/8th of the shell plate thickness, and never less than 13 mm thick.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
140Gusset Stays72%Chapter III (DPIIT scan), image 7
IBR 1950 regulation 140 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 140 page for its amendments.

Reg. 140
GIRDER STAYS
Gusset Stays

a) Gusset plates shall be flat and perpendicular to the end plates. The gusset angles shall be fitted to bed closely to the shell end plate and gusset plates. Cranking or setting of the plates is prohibited.
b) Gusset stays, where fitted, shall comprise flat plates secured by double angles to the shell and end plate respectively, and shall be designed in accordance with the following conditions.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
570
PDF page index
570 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 8c9c42ff16e59851
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 114, Regulation 114, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.570. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.