Indian Boiler Regulations, 2026 · Chapter 3 · Construction and Workmanship
Regulation 117. Fitting of plain tubes
Not yet checked against the official Gazette; verify before relying on it.
117. Fitting of plain tubes.─(1) Plain tubes shall be expanded at both ends. The expanding shall be parallel throughout the full thickness of the tube plate. Plain tubes may also be bell-mouthed, beaded, or welded at the gas inlet end.
(2)Where stay tubes are not fitted, the ends of the tubes shall be beaded over at the fire box end and beaded or bell-mouthed at the other end. If bell-mouthed, the tubes shall protrude not less than 13 mm beyond the tube plate.
In short
Regulation 117 sets how plain tubes are fixed in tube plates.
Key points
- (1) Plain tubes are expanded at both ends, with the expansion parallel through the full tube plate thickness. They may also be bell-mouthed, beaded or welded at the gas inlet end.
- (2) Where stay tubes are not fitted, tube ends are beaded over at the firebox end and beaded or bell-mouthed at the other. Bell-mouthed tubes protrude at least 13 mm beyond the tube plate.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 631 | Tubes | 100% | Chapter XV (DPIIT scan), image 3 |
| 212 | Holding power of plain tubes | 78% | Chapter IV (DPIIT scan), image 9 |
| 580 | Pitch of tubes | 73% | Chapter XII (DPIIT scan), image 9 |
IBR 1950 regulation 212 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 212 page for its amendments.
| Reg. 210, Reg. 211, Reg. 212 TUBE PLATES Parts to be stayed
Reg. 211 TUBE PLATES Minimum thickness and cross-section To provide a secure attachment for plain tubes in the tube plates the thickness and cross-section of the plate between the tube holes shall be not less than :- Steel tube plate .125D + .2 = minimum thickness in inches Eqn.(47) .17 + .025 = minimum cross section in square inches Eqn.(48) Copper tube plate, .2D + .4 = minimum thickness in inches Eqn.(49) .527D - .263 = minimum cross section in square inches Eqn.(50) D is the diameter in inches of the tube at the part of attachment to tube plate. Where the thickness and cross-section of the tube plates are less than the minimum the appropriate co-efficient in Eqn.(51) shall be reduced in proportion to the deficit. Reg. 212 TUBE PLATES Holding power of plain tubes
|
IBR 1950 regulation 580 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 580 page for its amendments.
| Reg. 580, Reg. 581 | |||||||||||||||||
Reg. 581 Stay tubes
| |||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 117, Regulation 117, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.570. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.