Indian Boiler Regulations, 2026 · Chapter 3 · Construction and Workmanship
Regulation 113. Breathing space
Not yet checked against the official Gazette; verify before relying on it.
113. Breathing space.─(1) Gusset stays shall be so arranged as to allow sufficient breathing space around furnace connections and the tube nests.
(2)For Lanchashire boilers, the proportions shown in the table below are recommended for portion of the end plates above the furnaces and flues.
Table 3/3
| Sl. No. | Thickness of End Plate | L (Fig.3/8) | L (Fig. 3/9) |
| (1) | (2) | (3) | (4) |
| mm | mm | mm | |
| 1 | 13 | 228 | 254 |
| 2 | 14 | 254 | 254 |
| 3 | 16 | 279 | 309 |
| 4 | 17 | 309 | 330 |
| 5 | 19 | 309 | 330 |
| 6 | 21 | 309 | 330 |
| 7 | Above 21 | 317 | 343 |
Table structure read from the Gazette PDF, page 569. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Sl. Thickness of End Plate L (Fig.3/8) L (Fig. 3/9)
No. (4)
mm
(1) (2) (3) 254
254
mm mm 309
330
1 13 228 330
330
2 14 254 343
3 16 279
4 17 309
5 19 309
6 21 309
7 Above 21 317
Fig. 3/8 Fig. 3/9(3)Fig. 3/8 shows the breathing space recommended for the following conditions: Flat end, furnace or flues flanged for attachment to end plate, furnaces and flues formed with Adamson flanged seams.
(4)Fig. 3/9 shows similar conditions to Fig. 3/8 except that the end plate is flanged outwards for the furnace or flue ring connection, the breathing spaces allowed being 25 mm more than those for the same thickness of plate in Fig. 3/8
(5)Where a corrugated section not less than 1830 mm long is included in each internal flue or a Lancashire boiler, the dimensions given in the table above may be reduced by approximately 38 mm throughout.
(6)It is recommended that the breathing space below the furnaces and flues shall be approximately one half of the dimensions given in the table above. Whereas it is desired to use any other arrangement which gives a greater or less degree or flexibility, the amount of breathing space shall be specially considered and modified as the necessity of the case requires.
(7)For Gusset stays above tube nests, as fitted in waste heat boilers without internal furnaces, a breathing space of 203 mm from the center line of the top tubes of the center of the toe rivets of the gusset angles is recommended (see Fig. 3/9).
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
Figures cited in this regulation (2, exact crops of the Gazette)

View Gazette page 569 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)

View Gazette page 569 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 113 requires gusset stays to leave enough breathing space (flexibility) around furnace connections and tube nests, and gives recommended dimensions for Lancashire boilers.
Key points
- (1) Gusset stays must allow sufficient breathing space around furnace connections and tube nests.
- (2) Table 3/3 gives recommended dimension L above the furnaces and flues for each end plate thickness, for the arrangements in Fig. 3/8 and Fig. 3/9.
- (3) Fig. 3/8 covers flat ends with furnaces or flues flanged to the end plate and Adamson flanged seams.
- (4) Fig. 3/9 is the same, except the end plate is flanged outwards for the furnace or flue ring. Breathing spaces are 25 mm more than in Fig. 3/8.
- (5) Where each internal flue includes a corrugated section at least 1830 mm long, the tabulated dimensions may be reduced by about 38 mm.
- (6) Below the furnaces and flues, about one half of the tabulated dimensions is recommended. Other arrangements need special consideration of the breathing space.
- (7) For gusset stays above tube nests in waste heat boilers without internal furnaces, 203 mm is recommended from the centre line of the top tubes to the centre of the gusset angle toe rivets.
Watch out
- These dimensions are stated as recommendations. The Table 3/3 columns are misaligned in the extracted text, so check the Gazette page for the values.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 141 | Breathing d furnace Conner a the table below are re | 75% | Chapter III (DPIIT scan), image 7 |
IBR 1950 regulation 141 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 141 page for its amendments.
| Reg. 141 GIRDER STAYS Breathing Space
|
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 113, Regulation 113, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.569–570. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.