Regulation 119. Stay tubes

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 571Table

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

119. Stay tubes.─(1) Stay tubes are tubes having a weld depth equal to the nominal tube thickness plus 3 mm. These stay tubes are not required within tube nests except when the tube nests comprise tubes which are expanded only.

(2)If tube nests comprise plain tubes that are expanded and beaded, expanded and belled or expanded and welded, welded stay tubes shall be used in boundary rows in sufficient numbers to carry the flat plate loadings outside the tube area.

(3)For plain tubes or stay tubes exposed to flame or gas temperatures exceeding 600°C, the ends of welded tubes shall be dressed flush with the welds. If not so exposed, the ends of welded tubes shall extend a maximum of 10 mm beyond the weld or, in the case of expanded tubes the tubes shall project beyond the tube plate up to a maximum of 15 mm.

(4)Each stay tube shall be designed to carry its due proportion of the load on the plates which it supports.

(5)The thickness of stay tubes welded into tube plates shall be such that the axial stress on the thinnest part of the tube does not exceed 7.14 kg/mm2.

(6)The thickness of stay tube at any part shall not be less than the values shown in the Table below. Minus tolerances shall be taken into account when ordering tubes.

Serial No.Nominal outside diameter in mmMinimum Thickness in mm
(1)(2)(3)
1.Not exceeding
38
2.28
2.Exceeding
38
but not exceeding 51
2.81
3.Exceeding
51
but not exceeding 70
3.12
4.Exceeding
70
but not exceeding 76.2
3.38
5.Exceeding
76.2
but not exceeding 88.9
3.96
6.Exceeding
88.9
but not exceeding 101.6
4.26
7.Exceeding
101.6
but not exceeding 127
4.55

Table structure read from the Gazette PDF, page 571. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Serial                                        TABLE 3/4      Minimum Thickness in mm
 No.               Nominal outside diameter in mm
 (1)                                                                        (3)
  1.                      (2)                                               2.28
  2.                                                                        2.81
  3.                      Not exceeding                  38                 3.12
  4.                                                                        3.38
  5.    Exceeding  38     but not exceeding 51                              3.96
  6.    Exceeding  51                                                       4.26
  7.    Exceeding  70     but not exceeding 70                              4.55
        Exceeding  76.2
        Exceeding  88.9   but not exceeding 76.2
        Exceeding  101.6
                          but not exceeding 88.9

                          but not exceeding 101.6

                          but not exceeding 127

Parts of this extracted text look garbled; read the Gazette page before using any value.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 119 defines stay tubes and sets when they are needed, how their ends are finished, their maximum axial stress and their minimum thickness.

Key points

  • (1) A stay tube has a weld depth equal to the nominal tube thickness plus 3 mm. They are not needed within tube nests unless the nests are of expanded-only tubes.
  • (2) Where nests are of plain tubes expanded and beaded, belled or welded, welded stay tubes are used in the boundary rows in enough numbers to carry the flat plate load outside the tube area.
  • (3) For tubes exposed to flame or gas over 600°C, welded tube ends are dressed flush with the weld. If not so exposed, welded tube ends extend at most 10 mm beyond the weld, and expanded tubes project at most 15 mm beyond the tube plate.
  • (4) Each stay tube carries its due share of the plate load.
  • (5) Welded-in stay tubes are thick enough that axial stress at the thinnest part does not exceed 7.14 kg/mm2.
  • (6) Table 3/4 gives minimum thickness by nominal outside diameter. Minus tolerances must be allowed for when ordering tubes.

Watch out

  • The diameter ranges in Table 3/4 are jumbled in the extracted text. Check the Gazette page for the exact values.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
147Screw Threads of Stay Tubes100%Chapter III (DPIIT scan), image 7
581Stay tubes100%Chapter XII (DPIIT scan), image 9
588Loads on Stay Tubes and Bar Stays100%Chapter XII (DPIIT scan), image 11

Amendment history of the candidate IBR 1950 regulations: Reg. 581 (3 amendments)

IBR 1950 regulation 147 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 147 page for its amendments.

Reg. 147
STAY TUBES
Screw Threads of Stay Tubes

a) Stay tubes shall be screwed at both ends with continuous threads, and the holes in the tube plates shall be tapped with continuous threads. The pitch of the threads shall not be finer than 11 threads per inch. The stay tubes shall be expanded by roller expanders and not made tight by caulking only.
b) Stay tubes may be attached by welding in which case they shall not be adjacent within the same tube next except in local areas, where not more than two adjacent stay tubes may be attached by welding. The form of attachment shall be such that there is a mechanical hold in addition to the welding, as shown in Figure 9A. On completion of welding the stay tubes shall be lightly re-expanded.
IBR 1950 regulation 581 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 581 page for its amendments.

Reg. 580, Reg. 581

Pitch of tubes

The spacing of tube holes shall be such that the minimum width in inches of any ligament between the tube holes shall be not less than:-

D + ½
8

alternatively,

the thickness and cross-section of the plate between the tube holes shall be not less than

0.125D+0.2=minimum thickness in inches.
0.17D+0.025=minimum cross-section in square inches where D is diameter of the tube holes in inches.

In no case shall the minimum thickness of any tube plate in the tube area be less than the following limits:-

T=1/2 inch, Where the diameter of the tube holes does not exceed 2 inches.
T=9/16 inch, Where the diameter of the tube hole is greater than 2 inches.



Reg. 581

Stay tubes

Stay tubes shall be of steel seamless or electrically resistance welded.
a) Minimum thickness of stay tubes – The minimum thickness of stay tubes shall be as per regulation 148.
b) The maximum working pressure for screwed in stay tube shall be calculated by the following formula:

WP = 5900         1.28
[(D---------------/N )² - D1²]
Equation XII/16
A

D is diameter of the stay tube over threads in inches.
D1 is internal diameter of the tubes under the threads in inches.
N is number of threads per inch.

A is the area in square inches supported by one Stay tube, measured from centre to centre of stay tubes. When the area contains tubes or parts of tubes their aggregate area, calculated from their smallest external diameter of body when in tension and smallest internal diameter when in compression, shall be deducted from the area of the containing figure and the remainder used as A in the formula.

Where stay tubes have their thickness increased at the screwed, ends to provide for plus threads the increased thickness shall be obtained by up-setting and not by welding, and the tubes shall be subsequently annealed.

Stay tubes may be attached to the tube plates either by screwing or by metal arc welding.

Where stay tubes are screwed into the tube plates they shall be screwed with a continuous thread not finer than 11 threads per inch at both ends and shall be expanded into the tube plates, by roller expander and, if desired, may be seal welded.

Welded attachment of stay tubes be as shown in Figure XII/67,XII/67A,XII/68, ,XII/68A and XII/69.
IBR 1950 regulation 588 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 588 page for its amendments.

Reg. 587, Reg. 588

Longitudinal Bar Stays

The maximum working pressure for longitudinal bar stays is to be calculated from the appropriate one of the following two formulae:

WP= C         1.28
(D - ------------)²
        N
Equation XII/21
A

WP= C x D1² Equation XII/22
A

WP is working pressure in pounds per square inch,
D is diameter of stays over threads in inches,
D1 is diameter of body of stays at its smallest part in inches,
N is the number of threads of stay per inch,
A is area in square inches supported by one stay.
C is values given in Table below:

TABLE XII/5
Stress on Longitudinal Bar Stays
Range of tensile strength of bar
Value of C
Tons per square inch Pounds per square inch
26/30 7850
28/32 8640
30/34 9420
32/36 10200

Where bar stays are fitted in vertical boilers, not less than four bar stays shall be fitted to boilers of 4 feet and over but under 5 feet in diameter; five bar stays to boilers of 5 feet and over but under 6 feet in diameter; six bar stays to boiler of 6 feet and over in diameter.

In no case, shall the diameter of the stay at any part be less than 1 inch. Where joined stays are fitted, the strength of the knuckle joint employed shall be at least equal to the strength of the remainder of the bar stay.


Reg. 588

Loads on Stay Tubes and Bar Stays

Stay tubes and bar stays shall be designed to carry the whole load due to the pressure on the area to be supported, the areas being calculated as follows:-

a) For a stay tube within the tube nest the net area to be supported shall be the product of the horizontal and vertical pitches, in inches, of the stay tubes less the area of the tube holes embraced. Where the pitch of the stay tubes is irregular the area shall be taken as the square of the mean pitch of the stay tubes (i.e., the square of ¼ of the sum of the four sides, of any quadrilateral bounded by four adjacent stay tubes), less the area of the tube holes embraced.
b) For a stay tube in the boundary row, or for a bar stay, the net area to be supported shall be the area, in square inches enclosed by lines passing midway between the stay and the adjacent points of support and by the boundary margin (see Regulation 589), less the area of any tubes or stays embraced.
c) In the case of a bar stay where there are no stay tubes in the tube nest the area to be supported shall extend to the tangential boundary of the tube nest.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
571
PDF page index
571 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 71d27b7005f7a0b4
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 119, Regulation 119, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.571. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.