109. Stay nuts.─ (1) Nuts of screw stays in combustion chambers and firebox shall not be less than 19 mm thick for stays up to 38 mm diameter over threads, 22 mm thick for 41 mm and 44 mm stays, 25 mm thick for 47 mm and 51 mm stays, and 28 mm thick for stays over 51 mm in diameter.
(2)The nuts shall be made of solid mild steel or of iron which shall be without weld, if exposed to flame.
In short
Regulation 109 sets the minimum thickness and material of nuts on screw stays in combustion chambers and fireboxes.
Key points
- (1) Minimum nut thickness by stay diameter over threads: 19 mm for stays up to 38 mm; 22 mm for 41 mm and 44 mm stays; 25 mm for 47 mm and 51 mm stays; 28 mm for stays over 51 mm.
- (2) Nuts are solid mild steel, or iron without weld, if exposed to flame.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 581 | Stay tubes | 74% | Chapter XII (DPIIT scan), image 9 |
Amendment history of the candidate IBR 1950 regulation: Reg. 581 (3 amendments)
IBR 1950 regulation 581 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 581 page for its amendments.
| Reg. 580, Reg. 581 | |||||||||||||||||
Reg. 581 Stay tubes
| |||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 109, Regulation 109, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.568. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.