Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 122 — Furnaces of Horizontal boilers
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 122 FURNACES Furnaces of Horizontal boilers
|
Earlier text: the 2008 DIPP web edition
FURNACES
GENERAL
Furnaces of Horizontal boilers
a)The sections of the internal flues shall each be in one plate and shall be bent while cold to circular form and shall be welded longitudinally.
b)The maximum permissible variation in diameter at any cross section shall not exceed the thickness of the plate.
c)The weld shall be placed at the lower part of the flues, and shall break joint in successive sections by at least 12 inches.
d)Each flange for the circular seams shall be formed at one heat by suitable machinery.
e)The sections shall be allowed to cool gradually to avoid internal stresses.
f)The caulking edges of all flue flanges shall be machined or machine gas cut. g The circular seams shall be arranged so that they do not fall in line with those of the adjacent flue or with the circumferential seams of the shell and are at least 6 inches apart.
h)When flues are flanged for attachment to both end plates the total length of each completed flue shall not exceed the length of the shell measured from the inner surface of the back end plate to the inner surface of the front end plate, both adjacent to the shell.
i)Where the flues are flanged for attachment to the end plates, the end sections shall be 1/16 inch thicker than the remaining sections, except in cases where the calculated thickness is over 13/16 inch, when the end section shall be 7/8 inch in thickness.
j)The flanged portion of furnace rings shall have radius of curvature of not less than 1 inch on water side.
k)Sections of corrugated flues may be fusion butt welded circumferentially and afterwards stress relieved by heat treatment.
l)As an alternative to Adamson flanges, furnaces which are partly fitted with corrugated sections shall be strengthened by means of suitable stiffening rings adequately welded to the furnaces. The moment of inertia of the stiffener shall be not less than that required by Regulation 592(b). In no case shall a flat stiffener be less than 63 mm. x 13 mm. (2½” x ½”).
Possible IBR 2026 successors (heading match, unverified): Reg. 94, Reg. 95, Reg. 96, Reg. 487, Reg. 488, Reg. 495, Reg. 497, Reg. 498