309. Transfer of memorandum of inspection book and registration book.─ On transfer of a boiler from one state to another, the memorandum of inspection book and the registration book shall, on the request of Chief Inspector of the state to which the boiler has been transferred, be forwarded to that officer who shall take over their custody and maintain them.
In short
When a boiler is transferred from one State to another, the Memorandum of Inspection Book and the registration book are forwarded to the Chief Inspector of the receiving State on that officer's request. That officer then takes custody of them and maintains them.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 528 | Memorandum of Inspection Book | 100% | Chapter XI (DPIIT scan), image 8 |
| 385 | Registration fee | 86% | Chapter IX (DPIIT scan), image 4 |
Amendment history of the candidate IBR 1950 regulations: Reg. 528 (1 amendment) · Reg. 385 (5 amendments)
IBR 1950 regulation 528 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 528 page for its amendments.
|
REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES | ||||||||||
| ||||||||||
|
REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES | ||||||||||
| ||||||||||
|
REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES | ||||||||||
|
IBR 1950 regulation 385 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 385 page for its amendments.
| Reg. 384
Reg. 385
| ||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 309, Regulation 309, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.707. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.