Indian Boiler Regulations, 2026 · Chapter 8 · Inspection and Testing of Boilers and Pipes during Construction and Boiler Registration

Regulation 305. Inspection fee for renewal of certificate

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 705–706Table

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

305. Inspection fee for renewal of certificate. ─ (1) The required fee to accompany an application under sub-section (3) of section 13 of the Act shall be as per table 8/3 of this regulation:

Provided that the Chief Inspector may direct that no fee shall be payable in respect of a fresh application made in pursuance of sub-section (2) of section 19 of the Act.

(2)Inspection fee for separately fired super-heater, re-heater and feed water heater shall be charged at the same rate.

(3)For heat recovery steam generators with finned tubes, the fee shall be calculated on heating surface area of bare tubes and on one fourth of heating surface area of fins.

(4)For renewal of certificate for a period of six months or less on the request of owner, half of applicable fee shall be payable.

(5)Applicable fee shall be payable again for the re-inspection of a defective boiler after completion of repairs.

(6)For inspection on Sundays or on any public holiday notified under the Negotiable Instrument Act, 1881 (26 of 1881), on the request of owner, additional fee equivalent to half of applicable fee shall be payable.

TABLE 8/3
Inspection fee for renewal of Certificate (regulation 305)

Serial No.Boiler RatingsFee in rupees
(1)(2)(3)
1For Small Industrial Boiler as per Chapter-14 and Small solar boilers as per
Chapter-17
1000
2For Boiler Rating not exceeding 10 sq. meters1600
3For Boiler Rating exceeding 10 sq. meters but not exceeding 30 sq. meters2100
4For Boiler Rating exceeding 30 sq. meters but not exceeding 50 sq. meters2400
5For Boiler Rating exceeding 50 sq. meters but not exceeding 70 sq. meters2700
6For Boiler Rating exceeding 70 sq. meters but not exceeding 90 sq. meters3400
7For Boiler Rating exceeding 90 sq. meters but not exceeding 110 sq. meters4000
8For Boiler Rating exceeding 110 sq. meters but not exceeding 200 sq. meters4500
9For Boiler Rating exceeding 200 sq. meters but not exceeding 400 sq. meters5000
10For Boiler Rating exceeding 400 sq. meters but not exceeding 600 sq. meters5800
11For Boiler Rating exceeding 600 sq. meters but not exceeding 800 sq. meters6300
12For Boiler Rating exceeding 800 sq. meters but not exceeding 1000 sq. meters7100
13For Boiler Rating exceeding 1000 sq. meters but not exceeding 1200 sq. meters8400
14For Boiler Rating exceeding 1200 sq. meters but not exceeding 1400 sq. meters9500
15For Boiler Rating exceeding 1400 sq. meters but not exceeding 1600 sq. meters11100
16For Boiler Rating exceeding 1600 sq. meters but not exceeding 1800 sq. meters11900
17For Boiler Rating exceeding 1800 sq. meters but not exceeding 2000 sq. meters13200
18For Boiler Rating exceeding 2000 sq. meters but not exceeding 2200 sq. meters14300
19For Boiler Rating exceeding 2200 sq. meters but not exceeding 2400 sq. meters15800
20For Boiler Rating exceeding 2400 sq. meters but not exceeding 2600 sq. meters16600
21For Boiler Rating exceeding 2600 sq. meters but not exceeding 2800 sq. meters18000
22For Boiler Rating exceeding 2800 sq. meters but not exceeding 3000 sq. meters19000
23For Boiler Rating exceeding 3000 sq. meters19000 + 500
for every 200
sq. meters or
part thereof

Table structure read from the Gazette PDF, page 706. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Serial  Boiler Ratings                                                                Fee in
 No.           (2)                                                                    rupees
 (1)
                                                                                        (3)
1 For Small Industrial Boiler as per Chapter-14 and Small solar boilers as per         1000
       Chapter-17
                                                                                       1600
2 For Boiler Rating not exceeding 10 sq. meters                                        2100
                                                                                       2400
3 For Boiler Rating exceeding 10 sq. meters but not exceeding 30 sq. meters            2700
                                                                                       3400
4 For Boiler Rating exceeding 30 sq. meters but not exceeding 50 sq. meters            4000
                                                                                       4500
5 For Boiler Rating exceeding 50 sq. meters but not exceeding 70 sq. meters            5000
                                                                                       5800
6 For Boiler Rating exceeding 70 sq. meters but not exceeding 90 sq. meters            6300
                                                                                       7100
7 For Boiler Rating exceeding 90 sq. meters but not exceeding 110 sq. meters           8400
                                                                                       9500
8 For Boiler Rating exceeding 110 sq. meters but not exceeding 200 sq. meters         11100
                                                                                      11900
9 For Boiler Rating exceeding 200 sq. meters but not exceeding 400 sq. meters         13200
                                                                                      14300
10 For Boiler Rating exceeding 400 sq. meters but not exceeding 600 sq. meters        15800
                                                                                      16600
11 For Boiler Rating exceeding 600 sq. meters but not exceeding 800 sq. meters        18000
                                                                                      19000
12 For Boiler Rating exceeding 800 sq. meters but not exceeding 1000 sq. meters   19000 + 500
                                                                                  for every 200
13 For Boiler Rating exceeding 1000 sq. meters but not exceeding 1200 sq. meters  sq. meters or
                                                                                   part thereof
14 For Boiler Rating exceeding 1200 sq. meters but not exceeding 1400 sq. meters

15 For Boiler Rating exceeding 1400 sq. meters but not exceeding 1600 sq. meters

16 For Boiler Rating exceeding 1600 sq. meters but not exceeding 1800 sq. meters

17 For Boiler Rating exceeding 1800 sq. meters but not exceeding 2000 sq. meters

18 For Boiler Rating exceeding 2000 sq. meters but not exceeding 2200 sq. meters

19 For Boiler Rating exceeding 2200 sq. meters but not exceeding 2400 sq. meters

20 For Boiler Rating exceeding 2400 sq. meters but not exceeding 2600 sq. meters

21 For Boiler Rating exceeding 2600 sq. meters but not exceeding 2800 sq. meters

22 For Boiler Rating exceeding 2800 sq. meters but not exceeding 3000 sq. meters

23 For Boiler Rating exceeding 3000 sq. meters

Parts of this extracted text look garbled; read the Gazette page before using any value.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Referenced provisions

Act s.13 · Act s.19

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 305 sets the inspection fee that must accompany an application to renew a boiler certificate under sub-section (3) of section 13 of the Act. The fee depends on the boiler rating and is given in Table 8/3.

Key points

  • (1) Table 8/3 has rows for small industrial boilers (Chapter-14) and small solar boilers (Chapter-17), then bands by boiler rating in square meters. See the Official text tab and the Gazette page for the values.
  • (2) Separately fired super-heaters, re-heaters and feed water heaters are charged at the same rate.
  • (3) Heat recovery steam generators with finned tubes: fee on the bare tube heating surface plus one fourth of the fin heating surface.
  • (4) Renewal for six months or less, at the owner's request: half the applicable fee.
  • (5) Re-inspection of a defective boiler after repairs: the applicable fee is payable again.
  • (6) Inspection on a Sunday or a public holiday notified under the Negotiable Instrument Act, 1881, at the owner's request: an additional fee equal to half the applicable fee.

Watch out

  • The Chief Inspector may direct that no fee is payable for a fresh application made under sub-section (2) of section 19 of the Act.
  • The extracted table layout is broken, so the fee figures do not line up cleanly with the rows. Check the Gazette page for the exact values.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
530Grant of certificate82%Chapter XI (DPIIT scan), image 9
524Preparation for inspection70%Chapter XI (DPIIT scan), image 7
IBR 1950 regulation 530 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 530 page for its amendments.


Reg. 529 A, Reg. 529 B, Reg. 530, Reg. 531

STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES

(a) Registration Books

Registration Books shall be maintained on the lines of Regulation 387.


Reg. 529 B

STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES

(b) Transfer of Memorandum of Inspection Book and Registration Books

On an economiser passing from one State to another, the Memorandum of Inspection and Registration Books shall, on the request of the Chief Inspector of the State to which the economiser has been transferred, be forwarded to that Officer who shall take over their custody and maintain them as prescribed.


Reg. 530

STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES

Grant of certificate

A certificate for the use of an economiser shall be granted in Form XI.


Reg. 531

STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES

Casual visits
a) The Inspector shall note if the economiser is working satisfactorily, and if the relief valves are correctly adjusted, if the scraper gear is operating and if the external brickwork is free from cracks.
b)

He shall also ascertain that the maker’s instructions for working are being strictly followed by the owner.

NOTE:- It is recommended that the feed inlet temperature to the economiser should not be less than 100°F. to prevent sweating and consequent external corrosion of the tube and bottom headers.

IBR 1950 regulation 524 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 524 page for its amendments.

Reg. 524, Reg. 525
STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES

Preparation for inspection

a)

At each inspection the economiser shall be emptied and thoroughly cleaned internally and externally and in the flues. All mountings shall be opened up and all caps, doors and blank flanges removed to permit adequate inspection.
b) The owner of an economiser to which this Regulation is applicable shall obtain the approval of the Chief Inspector in writing to the method of disconnection which he proposes to use and shall be responsible for ensuring that the method so approved is followed in practice.


Reg. 525

STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

REGULATIONS FOR REGISTRATION AND INSPECTION OF ECONOMISERS AND FEED PIPES

Procedure for Registration
a) On receipt of an application for registration the Inspector shall, after the economiser has been prepared for examination, take full particulars of the design and ascertain the working pressure allowed by the Regulations.
b)

The fitness of the economiser parts shall be determined as per the following formulae:-

(i)

Cast Iron Smooth Tube Economisers with Pressed Socket Joints.

WP = AZ + 225N Eqn.(124)
70a n

Where,

WP=Design pressure in pounds per square inch (gauge).
A= Area of contact surface of a single socket, square inches.
a= Cross sectional area measured on the mean diameter of a socket hole, in square inches.
Z=Breakdown load of an unreinforced socket joint in pounds.
N=Number of stays per header.
n=Number of sockets per header.

For existing standard designs the breakdown load of an unreinforced socket joint shall be taken as not greater than 13,500 lbs. For designs not already in use before the date of this standard the corresponding figure shall be taken as not greater than 75 per cent of the load as determined by experiment.
(ii) Headers of approximately rectangular cross section.

WP = C(t-2) Eqn.(125)
b²
Where,

t = Thickness in thirty-second of an inch.
b = Distance between the sides of header supporting the surface, in inches.
WP= Design pressure, in pounds per square inch (gauge)
C = 11 where the water side surface is flat

= 22 where the water side surface is curved, provided that the curvature is continued without interruption and the thickness at each end of the side is not less than that determined with C=11.

In no case, however, shall the thickness of the side of a header be less than 16 thirty-seconds of an inch at any part.
Next >>>

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
705–706
PDF page index
705–706 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash ef25674640bdd3ee
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 305, Regulation 305, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.705–706. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.