Indian Boiler Regulations, 2026 · Chapter 7 · Pipes and Fittings
Regulation 256. Steel pipes
Not yet checked against the official Gazette; verify before relying on it.
256. Steel pipes.─ The maximum allowable working pressure allowed on steel pipes shall be determined as per the following formula: -
(a)Where the outside diameter is the basis for calculation.
2 f E (t – C)
P = ------------- Equation (7/1)
D – t + C
Where, t = minimum thickness of pipe (mm),
P = maximum allowable working pressure (kg/cm2 (g)), f = allowable stress as provided under regulation 170(kg/cm2),
D = outside diameter of pipe (mm),
E = efficiency factor,
= 1.0 for seamless and for electric resistance welded steel pipes and for electric fusion welded steel pipes comply with the requirements of Chapter-2 in which the weld is fully radiographed or ultrasonically tested,
= 0.95 for electric fusion welded steel pipes complying with the requirements of Chapter-2,
= 0.90 for welded steel pipes for values of t up to and including 22 mm,
= 0.85 for welded steel pipes for values of t over 22 mm and up to and including 29 mm,
= 0.80 for welded steel pipes for values of t over 29 mm,
C = 0.75 mm.
The minimum thickness of pipe required shall be as per the following formula:
t= PxD +C Equation (7/2)
(2 x f x E) + P
Where, t = calculated minimum required thickness of pipe (mm),
P = maximum allowable working pressure (kg/cm2 (g)), f = allowable stress as provided under regulation 170(kg/cm2),
D = outside diameter of pipe (mm),
E = Ligament efficiency as per regulation 171,
C = 0.75 mm.
(b)Where the inside diameter is the basis for calculation.
2 f E (t – C)
P = ------------- Equation (7/3)
Where,
d + t – C
t = minimum thickness of pipe in mm,
P = maximum allowable working pressure (kg/cm2 (g)),
f = allowable stress as provided under regulation 170 (kg/cm2),
d = inside diameter of pipe (mm),
E = efficiency factor,
= 1.0 for seamless and for electric resistance welded steel pipes and for electric fusion welded
steel pipes comply with the requirements of Chapter-2 in which the weld is fully radiographed
or ultrasonically tested,
= 0.95 for electric fusion welded steel pipes complying with the requirements of Chapter-2,
= 0.90 for welded steel pipes for values of t up to and including 22 mm,
= 0.85 for welded steel pipes for values of t over 22 mm and up to and including 29 mm,
= 0.80 for welded steel pipes for values of t over 29 mm,
C = 0.75 mm.
The minimum thickness of pipe required shall be as per the following formula:
t= Pxd +C Equation (7/4)
(2 x f x E) - P
Where, t = calculated minimum required thickness of pipe (mm),
P = maximum allowable working pressure in kg/cm2 (g), f = Allowable stress as provided under regulation 170 (kg/cm2), d = inside diameter of pipe (mm),
E = Ligament efficiency as per regulation 171,
C = 0.75 mm.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 256 gives the formulae for the maximum allowable working pressure and minimum required thickness of steel pipes, based on either outside or inside diameter.
Key points
- (a) Outside diameter basis: pressure by Equation (7/1), thickness by Equation (7/2).
- (b) Inside diameter basis: pressure by Equation (7/3), thickness by Equation (7/4).
- Allowable stress f is as provided under regulation 170. C = 0.75 mm in all four equations. Pressure is in kg/cm2 (g); dimensions in mm.
- Efficiency factor E in the pressure equations:
- 1.0 for seamless and ERW pipes, and electric fusion welded pipes meeting Chapter-2 with the weld fully radiographed or ultrasonically tested;
- 0.95 for electric fusion welded pipes meeting Chapter-2;
- 0.90 for welded pipes with t up to and including 22 mm;
- 0.85 for welded pipes with t over 22 mm and up to and including 29 mm;
- 0.80 for welded pipes with t over 29 mm.
Watch out
- In the thickness equations (7/2) and (7/4), E is defined as ligament efficiency as per regulation 171, not the efficiency factor list above.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 351 | Cast Steel Pipes | 100% | Chapter VIII (DPIIT scan), image 5 |
Amendment history of the candidate IBR 1950 regulation: Reg. 351 (1 amendment)
IBR 1950 regulation 351 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 351 page for its amendments.
| Reg. 351 Cast Steel Pipes
|
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 256, Regulation 256, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.652–654. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.