Indian Boiler Regulations, 2026 · Chapter 7 · Pipes and Fittings
Regulation 252. Number of sets of mechanical tests
Not yet checked against the official Gazette; verify before relying on it.
252. Number of sets of mechanical tests .─ (1) The number of pipes on which mechanical tests are to be performed shall be as follows:-
| Table 7/2 | |
| Seamless pipes | As per regulation 49 |
| Welded pipes | 2 per cent of the lengths of pipes as made. |
Table structure read from the Gazette PDF, page 649. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Seamless pipes Table 7/2 Welded pipes As per regulation 49 2 per cent of the lengths of pipes as made.
(2)In the case of pipes for designed temperatures over 454°C, every pipe over 114 mm outside diameter shall be tested.
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
This regulation sets how many pipes must be mechanically tested.
Key points
- (1) The number of pipes to be tested is in Table 7/2: seamless pipes as per regulation 49, and welded pipes on 2 per cent of the lengths of pipes as made. The table layout is broken in the extracted text; check the Gazette page.
- (2) For pipes with design temperatures over 454°C, every pipe over 114 mm outside diameter must be tested.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 346 | Number of sets of tests | 100% | Chapter VIII (DPIIT scan), image 1 |
| 20 | Number of Bend Tests | 86% | Chapter II (DPIIT scan), image 2 |
| 89 | Mechanical test | 80% | Chapter II (DPIIT scan), image 18 |
Amendment history of the candidate IBR 1950 regulations: Reg. 20 (2 amendments) · Reg. 89 (1 amendment)
IBR 1950 regulation 346 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 346 page for its amendments.
| Reg. 346 MECHANICAL TESTS Number of sets of tests
|
IBR 1950 regulation 20 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 20 page for its amendments.
| Reg. 20 MATERIALS OF CONSTRUCTION STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL |
| (a) Plates.- A bend test shall be taken from each plate as rolled. The bend test from shell plates, butt straps and other plates which have not to be flanged or worked in the fire or which when in use are not to be exposed to flame shall be cold bend test. (b) Angle Bars.- A cold bend test shall be made from each angle bar rolled, provided that the cold bend test need not be carried out if basic material specification does not call for it. (c) Stay Bars.- A cold bend test shall be made from every 15 stay bars as rolled from each charge. |
IBR 1950 regulation 89 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 89 page for its amendments.
| Reg. 89 MATERIALS OF CONSTRUCTION GENERAL GREY IRON CASTINGS (GRADE A) Mechanical test |
| The casting must comply with the transverse and tensile tests specified in Regulation 90 and Regulation 91. All test pieces shall be selected by the Inspector and tested in his presence and to his satisfaction. |
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 252, Regulation 252, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.649. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.