Indian Boiler Regulations, 2026 · Chapter 7 · Pipes and Fittings
Regulation 272. Wrought Bends
Not yet checked against the official Gazette; verify before relying on it.
272. Wrought Bends.─ The minimum wall thickness at any point on the pipe bend shall be determined according to either of the following methods, namely :-
(a)(i)The minimum wall thickness at any point in the finished bend shall not be less than required by equation (7/2) or (7/4) given in regulation 256.
(ii)The bend thinning allowance shall be selected based on the manufacturing process to ensure the minimum thickness requirements after bending.
(iii)The bend thinning allowance thus selected is to be provided on all parts of the cross section of the pipe circumference without any detrimental effects on the final product.
(b)The minimum required thickness tm of a bend, after bending, in its finished form, shall be determined in accordance with equation (i) or (ii), namely:-
(c)
tm = P x D When outer diameter ‘D’ is the
+ C [equation (i)] basis for calculation
2 x (f x e / I) + P
tm = P x d + C [equation (ii)] When Inner diameter ‘d’ is the
2 x (f x e/I) - P basis forcalculation
where, tm = minimum wall thickness of a bend in mm,
P = maximum allowable working pressure in kg/cm²(g),
D = outside diameter of pipe in mm,
d = inside diameter of pipe in mm,
f = allowable stress as provided under regulation 170 in kg/cm², e = efficiency factor,
= 1.0 for seamless and for electric resistance welded steel pipes and for electric fusion welded steel pipes complying with the requirements of Chapter-2 in which the weld is fully radiographed or ultrasonically tested,
= 0.95 for electric fusion welded steel pipes complying with the requirements of Chapter-2,
= 0.90 for welded steel pipes for values of t (minimum thickness of pipe) up to and including 22 mm,
= 0.85 for welded steel pipes for values of t ( minimum thickness of pipe) over 22 mm and up to and including 29 mm,
= 0.80 for welded steel pipes for values of t (minimum thickness of pipe) over 29 mm,
C = 0.75 mm.
I = [4x (R/D) - 1] {at the intrados (inside of bend)},
[4x (R/D) - 2]
= [4x (R/D) +1] {at the extrados (outside of bend)},
[4x (R/D) +2]
= 1.0 {at the side wall of the bend centre line},
Where, R = Bend radius of pipe bend in mm (see figure below),
D= outside diameter of pipe
Thickness variations from the intrados to the extrados and at the ends of the bend shall be gradual and the minimum thickness requirements calculated above should be met at the extrados, intrados and bend centre line of the finished bend (see figure below).
The minimum thickness at the ends of the bends shall not be less than the requirements of equation (7/2) or (7/4) given in regulation 256 and the bend thinning allowance shall be selected based on the manufacturing process to ensure the minimum thickness requirements after bending.
Fig. 7/1
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
Figures cited in this regulation (1, exact crops of the Gazette)

View Gazette page 661 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
In short
This regulation sets how to find the minimum wall thickness of wrought pipe bends, by either of two methods.
Key points
- (a) Method one: thickness at any point in the finished bend must be at least that required by Equation (7/2) or (7/4) of regulation 256. A bend thinning allowance chosen for the manufacturing process must be provided around the whole cross section.
- (b) Method two: the minimum thickness tm of the finished bend is found from equation (i) (outside diameter basis) or equation (ii) (inside diameter basis). These use pressure P, diameter D or d, allowable stress f under regulation 170, efficiency factor e, C = 0.75 mm and a factor I.
- Efficiency factor e: 1.0 for seamless, ERW and fully radiographed or ultrasonically tested fusion welded pipes; 0.95 for other fusion welded pipes meeting Chapter-2; 0.90, 0.85 or 0.80 for welded pipes depending on t (up to and including 22 mm, over 22 mm up to and including 29 mm, over 29 mm).
- Factor I depends on R/D and differs at the intrados, extrados and side wall (where it is 1.0). See the Official text for the expressions.
- Thickness changes from intrados to extrados and at the bend ends must be gradual. The minimum must be met at the extrados, intrados and bend centre line.
Watch out
- The ends of the bend must also meet Equation (7/2) or (7/4) of regulation 256.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 145 | Steel and Wrought Iron Tubes | 70% | Chapter III (DPIIT scan), image 7 |
| 218 | Steel and Wrought Iron Tubes | 70% | Chapter IV (DPIIT scan), image 14 |
IBR 1950 regulation 145 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 145 page for its amendments.
| Reg. 145, Reg. 146 BOILER TUBES SUBJECT TO EXTERNAL PRESSURE Steel and Wrought Iron Tubes Both plain and stay smoke tubes may be made either of wrought iron or steel and may be electric-resistance-welded lap-welded or weldless. Reg. 146 BOILER TUBES SUBJECT TO EXTERNAL PRESSURE Fitting of Plain Tubes
|
IBR 1950 regulation 218 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 218 page for its amendments.
| Reg. 216, Reg. 217, Reg. 218, Reg. 219 BOILER AND SUPERHEATER TUBES SUBJECT TO INTERNAL PRESSURE The maximum working pressure for the tube shall be determined by equation No.87 (see Regulation 338). The maximum thickness of the tubes shall comply with the table given in Regulation 338 (b).
Where t = the thickness of the tubes in 100ths of an inch, D = the external diameter of the tubes in inches. (b) No tube shall be less than 12 S.W.G.(.104") thick. |
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 272, Regulation 272, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.660–662. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.