Regulation 272. Wrought Bends

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 660–662Figure referencedFormula / symbols

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

272. Wrought Bends.─ The minimum wall thickness at any point on the pipe bend shall be determined according to either of the following methods, namely :-

(a)(i)The minimum wall thickness at any point in the finished bend shall not be less than required by equation (7/2) or (7/4) given in regulation 256.

(ii)The bend thinning allowance shall be selected based on the manufacturing process to ensure the minimum thickness requirements after bending.

(iii)The bend thinning allowance thus selected is to be provided on all parts of the cross section of the pipe circumference without any detrimental effects on the final product.

(b)The minimum required thickness tm of a bend, after bending, in its finished form, shall be determined in accordance with equation (i) or (ii), namely:-

(c)

tm = P x D                                                 When outer diameter ‘D’ is the
                                       + C [equation (i)]  basis for calculation

            2 x (f x e / I) + P

tm = P x d                     + C [equation (ii)]         When Inner diameter ‘d’ is the
            2 x (f x e/I) - P                              basis forcalculation

where, tm = minimum wall thickness of a bend in mm,
P = maximum allowable working pressure in kg/cm²(g),
D = outside diameter of pipe in mm,
d = inside diameter of pipe in mm,
f = allowable stress as provided under regulation 170 in kg/cm², e = efficiency factor,

= 1.0 for seamless and for electric resistance welded steel pipes and for electric fusion welded steel pipes complying with the requirements of Chapter-2 in which the weld is fully radiographed or ultrasonically tested,

= 0.95 for electric fusion welded steel pipes complying with the requirements of Chapter-2,

= 0.90 for welded steel pipes for values of t (minimum thickness of pipe) up to and including 22 mm,

= 0.85 for welded steel pipes for values of t ( minimum thickness of pipe) over 22 mm and up to and including 29 mm,

= 0.80 for welded steel pipes for values of t (minimum thickness of pipe) over 29 mm,

C = 0.75 mm.

I = [4x (R/D) - 1] {at the intrados (inside of bend)},
[4x (R/D) - 2]

= [4x (R/D) +1] {at the extrados (outside of bend)},
[4x (R/D) +2]

= 1.0 {at the side wall of the bend centre line},

Where, R = Bend radius of pipe bend in mm (see figure below),
D= outside diameter of pipe

Thickness variations from the intrados to the extrados and at the ends of the bend shall be gradual and the minimum thickness requirements calculated above should be met at the extrados, intrados and bend centre line of the finished bend (see figure below).

The minimum thickness at the ends of the bends shall not be less than the requirements of equation (7/2) or (7/4) given in regulation 256 and the bend thinning allowance shall be selected based on the manufacturing process to ensure the minimum thickness requirements after bending.

Fig. 7/1

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Referenced provisions

Reg. 170 · Reg. 256

Figures cited in this regulation (1, exact crops of the Gazette)

Gazette Fig. 7/1
Fig. 7/1(no caption printed with this figure)
View Gazette page 661 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Independent explanation — not the law · draft · engineer review in progress

In short

This regulation sets how to find the minimum wall thickness of wrought pipe bends, by either of two methods.

Key points

  • (a) Method one: thickness at any point in the finished bend must be at least that required by Equation (7/2) or (7/4) of regulation 256. A bend thinning allowance chosen for the manufacturing process must be provided around the whole cross section.
  • (b) Method two: the minimum thickness tm of the finished bend is found from equation (i) (outside diameter basis) or equation (ii) (inside diameter basis). These use pressure P, diameter D or d, allowable stress f under regulation 170, efficiency factor e, C = 0.75 mm and a factor I.
  • Efficiency factor e: 1.0 for seamless, ERW and fully radiographed or ultrasonically tested fusion welded pipes; 0.95 for other fusion welded pipes meeting Chapter-2; 0.90, 0.85 or 0.80 for welded pipes depending on t (up to and including 22 mm, over 22 mm up to and including 29 mm, over 29 mm).
  • Factor I depends on R/D and differs at the intrados, extrados and side wall (where it is 1.0). See the Official text for the expressions.
  • Thickness changes from intrados to extrados and at the bend ends must be gradual. The minimum must be met at the extrados, intrados and bend centre line.

Watch out

  • The ends of the bend must also meet Equation (7/2) or (7/4) of regulation 256.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
145Steel and Wrought Iron Tubes70%Chapter III (DPIIT scan), image 7
218Steel and Wrought Iron Tubes70%Chapter IV (DPIIT scan), image 14
IBR 1950 regulation 145 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 145 page for its amendments.

Reg. 145, Reg. 146
BOILER TUBES SUBJECT TO EXTERNAL PRESSURE
Steel and Wrought Iron Tubes

Both plain and stay smoke tubes may be made either of wrought iron or steel and may be electric-resistance-welded lap-welded or weldless.


Reg. 146
BOILER TUBES SUBJECT TO EXTERNAL PRESSURE Fitting of Plain Tubes

a) Plain tubes shall be expanded at both ends. The expanding shall be parallel throughout the full thickness of the tube plate. Plain tubes may also be bell-mouthed, beaded, or welded at the gas inlet end.
b) Where stay tubes are not fitted, the ends of the tubes shall be beaded over at the fire box end and beaded or bell-mouthed at the other end. If bell-mouthed the tubes shall protrude not less than ¼ inch beyond the tube plate.
IBR 1950 regulation 218 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 218 page for its amendments.

Reg. 216, Reg. 217, Reg. 218, Reg. 219

BOILER AND SUPERHEATER TUBES SUBJECT TO INTERNAL PRESSURE

The maximum working pressure for the tube shall be determined by equation No.87 (see Regulation 338).

The maximum thickness of the tubes shall comply with the table given in Regulation 338 (b).

Reg. 217

HEADERS AND SECTION BOXES OF WATER TUBE BOILERS

See Eqn.(88), Reg. (340).

Reg. 218

BOILER TUBES (SMOKE ) SUBJECT TO EXTERNAL PRESSURE

Steel and Wrought Iron Tubes - (a) The maximum working pressure for the tubes shall be : -

W.P. = 100 (t - 6) Eqn.(56)
D

Where
t = the thickness of the tubes in 100ths of an inch,

D = the external diameter of the tubes in inches.

(b) No tube shall be less than 12 S.W.G.(.104") thick.

Reg. 219
HEADERS AND SECTION BOXES OF WATER TUBE BOILERS

Brass and Copper Tubes

The thickness of tapered brass and copper smoke tubes for locomotive boilers shall, in the case of tubes of an external diameter of 1-1/2 to 1-7/8 inches inclusive, be not less than 12 S.W.G. (.104inch) at the smoke-box end and10 S.W.G.(.128 inch) at the other end in the case of tubes of an external diameter of 2 to 2-3/8 inches inclusive, the thickness, at the smoke-box end shall not be less than 11 S.W.G. (.116 inch) and at the other end not less than 9 S.W.G. (.144 inch).

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
660–662
PDF page index
660–662 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash c0c78c55b1fa3d4d
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 272, Regulation 272, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.660–662. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.