232. Pressure Gauges Dials.─ (1) For pressure upto35 kg/cm2 (g), pressure gauge dials shall be graduated in kg/cm2(g) from zero to twice the pressure as nearly as may be practicable.

(2)For pressure exceeding 35 kg/cm2(g),the range of the graduation shall be from zero to one and a half times the maximum allowable working pressure, as nearly as may be practicable, but in no case shall the maximum graduation on the gauge be less than 70 kg/cm2 (g).

(3)The scale on the dial shall be clearly and permanently marked in kg/cm2 (g).

(4)The maximum allowable working pressure shall be marked in red on the dial of each pressure gauge.

(5)(a) Where the gauge is compensated for a head of water between the gauge and the boiler connection, the amount of such compensation shall be marked on the dial. Pressure gauge shall be calibrated within an accuracy of +1 percent.

(b)Boiler pressure gauges shall not be less than 150 mm in diameter.

(6)The travel of the pointer of the dial gauge shall not exceed 325°.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 232 sets how boiler pressure gauge dials are graduated, marked, sized and calibrated.

Key points

  • (1) For pressure up to 35 kg/cm²(g), dials are graduated in kg/cm²(g) from zero to twice the pressure, as nearly as practicable.
  • (2) For pressure exceeding 35 kg/cm²(g), the range is zero to one and a half times the maximum allowable working pressure, as nearly as practicable.
  • (3) The dial scale must be clearly and permanently marked in kg/cm²(g).
  • (4) The maximum allowable working pressure must be marked in red on every pressure gauge dial.
  • (5)(a) If the gauge is compensated for a water head between gauge and boiler connection, the compensation must be marked on the dial. Gauges must be calibrated within an accuracy of +1 percent (as printed; read as within 1 percent).
  • (5)(b) Boiler pressure gauges must be not less than 150 mm in diameter.
  • (6) Pointer travel must not exceed 325°.

Watch out

  • (2) Whatever the working pressure, the maximum graduation must never be less than 70 kg/cm²(g) for gauges in that range.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Original drawings for this regulation

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
327Dials100%Chapter VI (DPIIT scan), image 8

Amendment history of the candidate IBR 1950 regulation: Reg. 327 (1 amendment)

IBR 1950 regulation 327 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 327 page for its amendments.

Reg. 327, Reg. 328, Reg. 329
PRESSURE GAUGES

Dials

a) For pressure up to and including 35 kg/cm2, pressure gauge dial shall be graduated in kg/cm2 from zero to twice the pressure as nearly as may be practicable.
b) For pressure exceeding 35 kg/cm2 the range of the graduation shall be from zero to one and a half times the maximum permissible working pressure, as nearly as may be practicable, but in no case shall the maximum graduation on the gauge be less than 70 kg/cm2
c) The scale on the dial shall be clearly and permanent marked in kg/cm2.
d) The dial of each pressure gauge shall have to be marked upon it in red, the maximum permissible working pressure.
e) Where the gauge is compensated for a head of water between the gauge and the boiler connection, the amount of such compensation shall be marked on the dial. Pressure gauge shall be calibrated within an accuracy of ± 1%. Boiler pressure gauges shall not be less than 150 mm in diameter.
f) The travel of the pointer of the dial gauge shall not exceed 325o C.


Reg. 328

Connections

All pressure gauges shall be fitted with a syphon pipe and a cock or valve integral with, or adjacent to, the gauge in such manner that the gauge may be shut off and removed whilst the boiler is under steam.


Reg. 329

Gauge Cocks

The handles of the gauge cocks shall be parallel to the pipes in which they are located when the cocks are open and marks shall be cut on the shank of the cock indicating open position.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
639
PDF page index
639 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash b71316dec5be122f
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 232, Regulation 232, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.639. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.