Indian Boiler Regulations, 2026 · Chapter 5 · Valves, Gauges and Auxiliaries
Regulation 184. Castings
Not yet checked against the official Gazette; verify before relying on it.
184. Castings.─ (1)All castings shall be smooth, sound and free from flaws or other injurious defects. Variations in thickness at any part shall be gradual and substantial fillets shall be provided.
(2)The body of a boiler mounting shall be connected to the boiler flange by a strong and stiff neck. In no case, the thickness of the neck of bronze mounting shall be less than 5 mm for sizes up to and including 19 mm bore or 6 mm size over 19 mm bore.
In short
Regulation 184 sets quality and neck-thickness requirements for castings used in boiler mountings.
Key points
- (1) All castings must be smooth, sound and free from flaws or other injurious defects. Changes in thickness must be gradual, with substantial fillets.
- (2) The body of a mounting must be joined to the boiler flange by a strong and stiff neck.
Watch out
- For bronze mountings, the neck thickness must never be less than 5 mm for sizes up to and including 19 mm bore, or 6 mm for sizes over 19 mm bore.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 246 | Steel Castings | 100% | Chapter V (DPIIT scan), image 3 |
IBR 1950 regulation 246 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 246 page for its amendments.
|
| ||||||||
Reg. 247
Reg. 248
Reg. 249
| ||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 184, Regulation 184, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.626. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.