Indian Boiler Regulations, 2026 · Chapter 5 · Valves, Gauges and Auxiliaries
Regulation 214. Determination of Maximum Allowable Working Pressure
Not yet checked against the official Gazette; verify before relying on it.
214. Determination of Maximum Allowable Working Pressure.─(1)The maximum allowable working pressure to be allowed for steel springs of round, square or rectangular section shall be determined from the following formulae for springs in extension.
(a) Round section --- 10,000 πd3 Equation (5/9)
P = DACK Equation (5/10)
(b) Square Section --- 33,333d3
P = DACK
(c)Rectangular section ---
160,000 B2 H2 Equation (5/11) P =
DACK (3B + 1.8H)
Note: For Springs in Compression, the maximum allowable working pressure calculated by the above equation may be increased by 25 per cent.
Where, (all dimensions in inches):-
4 (D – 1)/d 0.615 Equation (5/12)
K = +
D D
(In case of rectangular section substitute B for d)
P = maximum allowable working pressure in lb. Square inch (set pressure)
A = Loading area of valve,
D = diameter of round or side of square steel,
B = Breadth of wire (radial to spring axis).
H = Depth of wire (parallel to spring axis).
D = Mean diameter of coil,
L1 + L2 Equation (5/13)
C = Constant = ---------
L1
L1 = Initial compression or extension of the spring to give the required loading (P x A), L2 = the further compression or extension of the spring to give the lift as defined in regulations
193 to 195 and 207.
EXAMPLES:
C = 2 where compression or extension of spring to give the required loading is ¼ diameter of
valve.
C = 1.5 where compression or extension of spring to give the required loading is ½ diameter of
valve.
C = 1.25 where compression or extension of spring to give the required loading is full diameter
of valve.
Note: (1) The above formulae are based on the maximum allowable safe stress of 5,624 kg/cm2(g) on the section of the springs under extension and 7,030 kg/cm2(g) where they are in compression.
(2)The above values of “C” apply only to the case of “full-lift” Safety Valves, where L2 is equal D/4 in case of “high-lift” and “ordinary lift” Safety Valves, respective values of “C” may be worked out by using appropriate values of L2.
(2)In the case of torsion bars, the maximum shear stress as calculated from the following formula shall not exceed 55 kg/mm2.
TDC Equation (5/14)
fs = -------
2J
Where, fs = Shear stress
T = Torque at set pressure,
D = Outside diameter of the bar,
J = Polar moment of inertia of the section the bar, and
C = Angle of twist at full lift valve
---------------------------------------
Angle of twist at set pressure
(as furnished by the manufacturer).
The dimensions of sleeve transmitting the torque shall be of substantial proportions for the material used.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 214 gives the formulae for the maximum allowable working pressure (set pressure) for steel safety valve springs in extension, and a shear stress limit for torsion bars.
Key points
- (1) Equations (5/9), (5/10) and (5/11) cover round, square and rectangular section springs. They use the loading area of the valve (A), wire size (d, or B and H for rectangular wire), mean coil diameter, a factor K from Equation (5/12) and a constant C from Equation (5/13).
- C is based on L1 (initial compression or extension for the required load) and L2 (further compression or extension for the lift defined in regulations 193 to 195 and regulation 207). Worked values of C are 2, 1.5 and 1.25 where the initial compression or extension is ¼, ½ and the full valve diameter.
- For springs in compression, the pressure from these equations may be increased by 25 per cent.
- The formulae are based on safe stresses of 5,624 kg/cm²(g) in extension and 7,030 kg/cm²(g) in compression (stresses; the "(g)" is as printed).
- (2) For torsion bars, the shear stress from Equation (5/14) must not exceed 55 kg/mm². C there is the ratio of the angle of twist at full lift to that at set pressure, as furnished by the manufacturer.
Watch out
- All dimensions in these spring formulae are in inches and the pressure is in lb per square inch.
- The worked values of C apply only to full lift valves. For high lift and ordinary lift valves, work out C using the appropriate L2 (the text says L2 equals D/4).
- The sleeve transmitting the torque on a torsion bar must be of substantial proportions.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 434 | Determination of Working Pressure | 100% | Chapter X (DPIIT scan), image 9 |
IBR 1950 regulation 434 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 434 page for its amendments.
| Reg. 431, Reg. 432, Reg. 433, Reg. 434
Reg. 432
Reg. 433
Reg. 434
|
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 214, Regulation 214, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.634–636. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.