BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 2026 · Chapter 5 · Valves, Gauges and Auxiliaries

Regulation 225. Water Gauges

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 638

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

225.Water Gauges.─(1)Every boiler shall have two means of indicating the water in it, out of which one shall be conventional gauge glass:

Provided that in the case of boiler drums below 91 cm diameter where there is difficulty in fitting two water gauges, two test cocks and a glass water gauge shall be fitted.

(2)(a) The lowest visible part of the glass of the water gauge and lower test cocks shall be fixed at safe working level.

(b)For locomotive type and vertical boilers this shall not be less than 50 mm above the highest part of the firebox roof plate. Minimum length of the visible portion of the gauge glasses shall be 200 mm.

(c)The length may be increased depending upon the capacity of the boiler by the Inspecting Authority.

(3)(a) Glass water gauges shall be so placed as to be easily seen and reached by the boiler attendant.

(b)The fittings of glass water gauges and test cocks shall be of substantial make with large passage ways through them to facilitate cleaning.

(c)The gauge cocks when open shall have their handles in a vertical direction and each handle at its junction with the plug shall be plainly marked with a deep line to indicate the direction of the passage way through the plug.

(d)When detachable handle are provided arrangement shall be made to prevent incorrect fitting of the handles.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 225 requires every boiler to have two means of indicating water level, one of which is a conventional gauge glass, and sets where and how water gauges are fitted. See also the fittings list in regulation 181.

Key points

  • (1) Two means of indicating water level, one a conventional gauge glass.
  • (2)(a) The lowest visible part of the gauge glass and the lower test cocks are fixed at safe working level.
  • (2)(b) For locomotive type and vertical boilers, this level must be not less than 50 mm above the highest part of the firebox roof plate. The visible part of gauge glasses must be at least 200 mm long.
  • (2)(c) The Inspecting Authority may increase the length depending on boiler capacity.
  • (3)(a) Glass gauges must be easily seen and reached by the boiler attendant.
  • (3)(b) Gauge and test cock fittings must be substantial, with large passage ways for cleaning.
  • (3)(c) Gauge cock handles must be vertical when open, and each handle must be deeply marked to show the direction of the passage through the plug.
  • (3)(d) Detachable handles must be arranged so they cannot be fitted incorrectly.

Watch out

  • Proviso to (1): for boiler drums below 91 cm diameter where two gauges are hard to fit, two test cocks and a glass water gauge are fitted instead.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Original drawings for this regulation

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

No candidate heading found in the historical print edition.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
638
PDF page index
638 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash cf719ef14a47cebb
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 225, Regulation 225, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.638. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.