Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 327 — PRESSURE GAUGES
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 328, 329. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 327, Reg. 328, Reg. 329 | |||||||||||||||
Reg. 328 Connections
Reg. 329 Gauge Cocks
|
Earlier text: the 2008 DIPP web edition
PRESSURE GAUGES
Dials
a)For pressure up to and including 35 kg/cm², pressure gauge dial shall be graduated in kg/cm² from zero to twice the pressure as nearly as may be practicable.
b)For pressure exceeding 35 kg/cm² the range of the graduation shall be from zero to one and a half times the maximum permissible working pressure, as nearly as may be practicable, but in no case shall the maximum graduation on the gauge be less than 70 kg/cm²
c)The scale on the dial shall be clearly and permanent marked in kg/cm².
d)The dial of each pressure gauge shall have to be marked upon it in red, the maximum permissible working pressure.
e)Where the gauge is compensated for a head of water between the gauge and the boiler connection, the amount of such compensation shall be marked on the dial. Pressure gauge shall be calibrated within an accuracy of ± 1%. Boiler pressure gauges shall not be less than 150 mm in diameter.
f)The travel of the pointer of the dial gauge shall not exceed 325o C.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 1969-03-01/1988-12-31 | compilation-1969-1988#p61 OCR of compilation | Substituted | Replaces regulation 327 (dials of pressure gauges). | listed before the capture |
Possible IBR 2026 successors (heading match, unverified): Reg. 232