Indian Boiler Regulations, 2026 · Chapter 4 · Fusion Welded Drums for Water Tube Boilers and Superheaters

Regulation 180. Attachment of stand blocks and branch pipes by welding

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 617–618Figure referencedFormula / symbols

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

180. Attachment of stand blocks and branch pipes by welding.─ (1)Typical methods of attachment are shown in figures, namely:-

Fig. 4/24, 4/25, 4/26, 4/27, 4/28, 4/29, 4/30, 4/31, 4/32, 4/33, 4/34, 4/35 and 4/36.

All weld dimensions shown shall be regarded as minimum dimensions those defining the grooves refer to the actual preparation for welding.

tn = Specified thickness of standpipe or branch pipe.
ts = Specified thickness of drum or header shell at standpipe or branch connection. te = Actual thickness of compensating ring.

The application of certain of the constructions illustrated may be limited by consideration of design pressure and temperature or size (in combination) and although certain dimensions are given, each case must be considered on its merits.
Other methods may be adopted subject to agreement between the Inspecting Authority and manufacturer.

(2)Welding consumables shall comply with the requirements of regulation 71 to 76.

(3)Not less than two runs of metal shall be deposited at each weld. Each run of weld metal shall be thoroughly cleaned and freed from slag before the next run is deposited. In the case of water tube boiler or boilers fitted with super heater, the feed water connection and stop valve need not be shut off and if the total valve area is lifted and found to be adequate by calculations, the requirement of the accumulation test may be assumed to have been satisfied if the valves area has been found so adjusted that at least one safety valve on each boiler shall lift at or below the design pressure of the boiler and all valves shall lift so that are steam which can be generated by the boiler can be discharged with a pressure rise not exceeding 10 per cent of the design pressure.

(4)The final finish of the weld shall be such that change of section from drum to standpipe, or from flange to standpipe is gradual and free from sharp notches. After completion of welding (except in the case of seal welds) the drum shall be stress-relieved by heat treatment.

Fig. 4/24: Welded in Stand Pipe or Branch for Stand Fig. 4/25: Welded to Stand Pipe or Branch or Pipes and Branches up to and including 101.6 mm Bore Branches up to any and including 101.6 mm Bore

Parts of this extracted text look garbled; read the Gazette page before using any value.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Referenced provisions

Reg. 71 · Reg. 76

Figures cited in this regulation (13, exact crops of the Gazette)

Gazette Fig. 4/24: Welded in Stand Pipe or Branch for Stand Pipes and Branches up to and including 101.6 mm Bore
Fig. 4/24Welded in Stand Pipe or Branch for Stand Pipes and Branches up to and including 101.6 mm Bore
View Gazette page 618 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/25: Welded to Stand Pipe or Branch or Branches up to any and including 101.6 mm Bore
Fig. 4/25Welded to Stand Pipe or Branch or Branches up to any and including 101.6 mm Bore
View Gazette page 618 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/26: Welded in Stand Pipe or Branch with Compensating Ring for Stand Pipes or Branches including 101.6 mm Bore
Fig. 4/26Welded in Stand Pipe or Branch with Compensating Ring for Stand Pipes or Branches including 101.6 mm Bore
View Gazette page 619 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/27: Welded in Stand Pipe or Branch with Compensating Ring For Stand Pipes and Branches up to and including 101.6 mm Bore
Fig. 4/27Welded in Stand Pipe or Branch with Compensating Ring For Stand Pipes and Branches up to and including 101.6 mm Bore
View Gazette page 619 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/28
Fig. 4/28(no caption printed with this figure)
View Gazette page 619 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/29: Screwed and Seal Welded Connection
Fig. 4/29Screwed and Seal Welded Connection
View Gazette page 619 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/30: Welded in Stand Pipe or Branch with Compensating Ring
Fig. 4/30Welded in Stand Pipe or Branch with Compensating Ring
View Gazette page 620 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/31: Welded in Stand Pipe or Branch
Fig. 4/31Welded in Stand Pipe or Branch
View Gazette page 620 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/32: Welded in Stand Pipe or Branch
Fig. 4/32Welded in Stand Pipe or Branch
View Gazette page 620 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/33: Branch Welded on Header with Internal Machinery
Fig. 4/33Branch Welded on Header with Internal Machinery
View Gazette page 620 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/34
Fig. 4/34(no caption printed with this figure)
View Gazette page 620 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/35: Unreinforced Branches Inaccessible for Welding Inside Shell
Fig. 4/35Unreinforced Branches Inaccessible for Welding Inside Shell
View Gazette page 621 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Gazette Fig. 4/36: Unreinforced Branches Inaccessible for Welding Inside Shell
Fig. 4/36Unreinforced Branches Inaccessible for Welding Inside Shell
View Gazette page 621 · figure catalogue
Reconstructed CAD: DXF · SVG · Preview (redrawn, checked against the print; technical review pending)
Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 180 covers welding of stand blocks and branch pipes to drums and headers.

Key points

  • (1) Figs. 4/24 to 4/36 show typical attachment methods. Weld dimensions shown are minimums; groove dimensions are the actual preparation. Some constructions may be limited by pressure, temperature or size, and each case is considered on its merits. Other methods need agreement between the Inspecting Authority and manufacturer.
  • (2) Welding consumables must meet regulations 71 to 76.
  • (3) At least two runs per weld, each cleaned of slag before the next.
  • (4) The finished weld must give a gradual change of section, free from sharp notches. After welding (except seal welds) the drum must be stress relieved.

Watch out

  • Sub-regulation (3) also contains text about safety valve lift and accumulation tests that does not appear to relate to welding. Check the Gazette page.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
8Welding100%Chapter I (DPIIT scan), image 3

Amendment history of the candidate IBR 1950 regulation: Reg. 8 (2 amendments)

IBR 1950 regulation 8 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 8 page for its amendments.

Reg. 8
Welding:-

(a) The use of welding in the construction of boilers shall be permitted only where specifically provided for in the standard conditions.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
617–618
PDF page index
617–618 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 3fcbc285e9c42a8a
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 180, Regulation 180, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.617–618. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.