Independent explanation — not the law · draft · engineer review in progress
In short
Internal doors in this Chapter must meet the requirements of regulation 137.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
IBR 1950 regulation 567 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 567 page for its amendments.
Reg. 567, Reg. 567A
Dished ends subject to internal pressure
a)
For unstayed ends of shells and tops of vertical boilers and the like boiler parts, when dished to partial spherical form the maximum working pressure shall be determined by the following formula:-
WP =
15 x S X (t-1)
Equation XII/7
R
WP is the working pressure in pounds per square inch.
t is thickness of the end plate in thirty seconds of an inch but in no case this shall be less than the thickness of the shell to which it is attached.
R is the inner radius of curvture of the end in inches, which shall not exceed the external diameter of the shell to which it is attached.
S is the minimum tensile breaking strength of plate in tons per square inch, or whatever is allowed for it.
b)
The inside radius to which a crown plate is dished shall be not greater than the external diameter of the cylinder to which it is attached.
c)
The inside radius of curvature of the flanges to the shell shall be not less than 4 times the thickness of the crown plate and in no case less than 2 ½ inches.
d)
The inside radius of curvature of flanges to uptakes shall be not less than twice the thickness of the crown plate and in no case less than 1 inch.
e)
When the end has a manhole in it (t-5), shall be substituted for (t -1) in the formula.
f)
The total depth of flange of manhole from the outer surface in inches measured on the minor axis shall be at least equal to-
ÖT X W depth of flange in inches
Equation XII/8
where T is the thickness of the plate in inches and W is the minor axis of the hole in inches.
g)
The depth of the crown plate opening from the commencement of the curvature of the flanging radius shall be not less than twice the plate thickness with a minimum of one inch.
Reg. 567A
Nothing in Regulation 567 shall preclude the use of dished ends in compliance with Regulations 275 to 278, where not fitted with an uptake.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.
pdftotext layout mode, sequential regulation detector · text hash 142a13dd8806a12d
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite
Indian Boiler Regulations, 2026, reg. 178, Regulation 178, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.614. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.