BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 2026 · Chapter 4 · Fusion Welded Drums for Water Tube Boilers and Superheaters

Regulation 161. Bend tests

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 593–594Table

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

161. Bend tests.─ (1)The specimen shall be mounted in such a way that the axis of the former is in the middle of the weld, and on roller supports the faces of which are separated by a distance determined by the thickness of the specimen.

(2)The best specimen shall be pushed through the supports by a former having a diameter also determined by the thickness of the specimen. The requirements of table 4/3 given below, relating to the thickness of test specimen, shall apply.

(3)On completion of the test, no crack or defect on the outer surface of the specimen shall be greater than 1.5 mm measured across the specimen, or 3 mm measured along the specimen. Premature failure at the comers of the specimen shall not be considered as a cause for rejection.

Table 4/3: Bend Test Requirements

Serial NumberSpecified minimum tensile strength of plateDiameter of FormerFree space between support at the end of list
(1)(2)(3)(4)
(i)Below 44 kgf/mm22 T4.2 T
(ii)From 44 to 54 kgf/mm23 T5.2 T
(iii)Above 54 kgf/mm24 T6.2 T

Table structure read from the Gazette PDF, page 594. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Serial Number  Specified minimum tensile  Diameter of    Free space between
               strength of plate            Former     support at the end of list

(1)            (2)                        (3)          (4)

(i)            Below 44 kgf/mm2           2 T          4.2 T

(ii)           From 44 to 54 kgf/mm2      3 T          5.2 T

(iii)          Above 54 kgf/mm2           4 T          6.2 T

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 161 sets how bend tests are run and judged.

Key points

  • (1) The specimen sits on roller supports with the former's axis at the middle of the weld. Support spacing depends on specimen thickness.
  • (2) The specimen is pushed through by a former whose diameter also depends on thickness. Table 4/3 gives former diameter and free space in terms of specimen thickness T, for plates below 44, from 44 to 54, and above 54 kgf/mm² minimum tensile strength. See the Official text tab for values.
  • (3) After the test, no crack or defect on the outer surface may exceed 1.5 mm across or 3 mm along the specimen.

Watch out

  • Premature failure at the corners of the specimen is not a reason for rejection.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
20Number of Bend Tests100%Chapter II (DPIIT scan), image 2
19Bend Tests100%Chapter II (DPIIT scan), image 2
84Bend Tests100%Chapter II (DPIIT scan), image 16

Amendment history of the candidate IBR 1950 regulations: Reg. 20 (2 amendments) · Reg. 19 (1 amendment)

IBR 1950 regulation 20 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 20 page for its amendments.

Reg. 20
MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Number of Bend Tests

(a) Plates.- A bend test shall be taken from each plate as rolled. The bend test from shell plates, butt straps and other plates which have not to be flanged or worked in the fire or which when in use are not to be exposed to flame shall be cold bend test.

(b) Angle Bars.- A cold bend test shall be made from each angle bar rolled, provided that the cold bend test need not be carried out if basic material specification does not call for it.

(c) Stay Bars.- A cold bend test shall be made from every 15 stay bars as rolled from each charge.

IBR 1950 regulation 19 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 19 page for its amendments.

Reg. 19
MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Bend Tests

Cold Bends.-(a) Test pieces shall be sheared lengthwise or crosswise from plates or bars, and shall not be less than 1½ inches wide, but for small bars the whole section may be used. For rivet bars bend tests are not required.

b) In all cold bend tests, on samples 0.5 inch in thickness and above, the rough edge or arris caused by shearing may be removed by filing or grinding, and samples 1 inch in thickness and above may have the edges machined, but the test pieces shall receive no other preparation. The test pieces shall not be annealed unless the material from which they are cut is similarly annealed in which case the test piece shall be similarly and simultaneously treated with the material before testing. 

(c) (i) For bend test of plates of all grades of steel, the test piece shall withstands, without fracture, being bent cold through 180o around a mandrel, the radius of which shall have a relationship to the plate thickness as given below:

      Tensile strength                          Mandrel Radius

      36 - 49 kg./mm2                              1 T

      41 - 57 kg./mm2                              1 T

      45 - 64 kg./mm2                            1.5 T

where T = Plate thickness  

(ii) For cold bend test of sections and bars, the test piece shall withstand, without fracture, being doubled over until the internal radius is equal to that shown in Table under regulation 16 and the limbs are parallel.

(d) For small sectional material these bend tests may be made from the flattened bar.

(e) Bend tests may be made either by pressure or by blows.

IBR 1950 regulation 84 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 84 page for its amendments.

Reg. 84
MATERIALS OF CONSTRUCTION

FORGED OR ROLLED PRESSURE PARTS OTHER THAN SEAMLESS DRUMS OF CARBON STEEL

Bend Tests

(a) Bend test pieces shall be of rectangular cross section machined to a finished size of 1 inch wide by ¾ inch thick. In the case of headers, bend test pieces may be cut transversely 1½ T wide by T thick where T is the thickness of the header. The edges shall be rounded to a radius of 1/16 inch. The test pieces shall be bent over the thinner section.

(b) Test pieces shall be bent when cold through an angle of 180° without fracture, the internal radius of the bend being not greater than that specified in table below for the 1 inch wide by ¾ inch thick test piece and not more than 1½ T for the full thickness test piece:

Ultimate tensile stress

Internal radius of bend

Tons/sq. inch

Inch

Upto 32 1/4
Above 32 and upto 36 3/8
Above 36 and upto 38 5/8

Bend tests may be made by pressure or by blows.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
593–594
PDF page index
593–594 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 8bf2d79ca49602f6
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 161, Regulation 161, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.593–594. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.