162. Notched-bar-impact test.─ (1) The notched bar impact test specimens shall be of the type and dimension as shown in Fig. 4/7, the notch shall be contained in the weld-metal at approximately the axis of the weld and the axis of the notch is to be perpendicular to the surface of the plate.
(2)The test shall be carried out as follows:
For the V-Notch specimen at a temperature of 20 ± 2°C. In the case of V-Notch specimen, the machining of the bottom of the notch shall be done very carefully. The minimum result to be obtained from the impact test pieces shall be:
(a)V-Notch specimen: 3.46 kgfm/cm2
(b)One test shall consist of three test specimens and the value specified above is the average of three specimen values.
(c)Out of the three values, no single value shall be less than one third of the average value.
Note: Above value is equivalent to 2.76 kgfm divided by sectional area below the notch.
All dimensions are in mm.
Fig. 4/7: Standard V-Notch Test Piece
Figures cited in this regulation (1, exact crops of the Gazette)

View Gazette page 594 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 162 sets the notched-bar (Charpy V-notch) impact test for weld metal.
Key points
- (1) Specimens follow Fig. 4/7, with the notch in the weld metal at about the weld axis and the notch axis perpendicular to the plate surface.
- (2) The test is at 20 ± 2°C; the notch bottom must be machined very carefully.
- (2)(a)–(b) Minimum result for V-notch: 3.46 kgfm/cm², as the average of three specimens.
- (2)(c) No single value may be less than one third of the average.
- The Note says this equals 2.76 kgfm divided by the sectional area below the notch.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 162, Regulation 162, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.594. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.