Indian Boiler Regulations, 2026 · Chapter 2 · Materials of Construction
Regulation 71. COVERED ELECTRODES FOR SHIELDED METAL ARC WELDING
Not yet checked against the official Gazette; verify before relying on it.
71.COVERED ELECTRODES FOR SHIELDED METAL ARC WELDING.─(1) (a)(i)This regulation shall apply to covered electrodes of sizes 2.0 mm and larger in diameter for shielded metal arc welding of carbon steel, low alloy steels, stainless steels and non-ferrous materials;
(ii)Electrodes of less than 2.0 mm in diameter shall not be used in boilers.
(b)The covered electrode shall comply with the requirements specified in these regulations.
(c)The characteristics and behaviour under ordinary working conditions shall be such that satisfactory weld deposits can be made by a welder of average skill and experience and that the following characteristics are obtained, namely:-
(i)relative ease in the control of the slag and weld metal during welding;
(ii)good degree of stability of the arc;
(iii)no undue degree of spatter;
(iv)desired rate of deposition and depth of penetration.
(v)easy removability of the slag;
(vi)no undue tendency to under-cut;
(vii)desired contour of the weld deposits: and
(viii)low internal porosity of the weld metal.
(2)The covered electrodes shall be classified into following categories and in accordance with applicable Specifications for Filler Alloys (SFA) of American Society of Mechanical Engineers (ASME) Part IIC specifications or AWS (American Welding Society) specifications or equivalent:
(a)Carbon steel electrodes
(b)Low alloy steel electrodes
(c)Stainless steel electrodes
(d)Nickel and nickel-alloy welding electrodes
(3)Covered electrodes may be made by any method that shall yield a product conforming to the requirements of these regulations and relevant Specifications for Filler Alloys (SFA) or American Welding Society (AWS) specification.
(4)(a)The nominal size of the covered electrodes shall refer to the diameter of the core wire and the length shall not exceed 450 mm with provision for end gripping.
(b)The tolerance on the specified diameter of the core wire of the electrodes shall be ± 0.05 mm.
(c)The tolerance on the length of the electrodes shall be ±10 mm or as specified in relevant Specifications for Filler Alloys (SFA) or American Welding Society (AWS) specifications.
(5)(a)The core wire and covering shall be free from defects that would interfere with the uniform deposition of electrode.
(b)The flux covering shall be sufficiently robust to withstand the normal conditions of transport, storage, handling and use, without damage and shall be uniform in thickness all over so that it fuses evenly.
(c)The covering shall be concentric with core and the permissible variation on maximum core plus one covering shall not exceed the minimum core plus one covering as under:
(i)For diameter up to 2.5 mm 7 % of mean dimension,
(ii)For diameter 3.2 to 4.0 mm 5 % of mean dimension, and
(iii)For diameter 5 mm and larger 4 % of mean dimension.
(6)At least one imprint of electrode classification shall be imprinted at the covering within 65 mm of grip end. The imprinting shall be legible both before and after welding.
(7)(a)Covered electrodes shall be suitably packed to guard against damage during transportation. When stored, the electrodes shall be kept in their original bundles or packing in a dry store room and under such conditions, the electrodes shall be capable of giving results similar to those which they would have given on the date of their dispatch from the manufacturer for a period of two years or as recommended by the electrode manufacturer whichever is less. Usage of electrodes beyond this period may be permitted after conducting check tests as per specification, provided it is not restricted by the electrode manufacturer.
(b)Each package shall be marked with the following information.
(i)Name of the Manufacturer.
(ii)Trade name / Brand name of the electrodes.
(iii)Size and quantity of electrodes.
(iv)Batch Number and date of manufacture.
(v)Recommended current range.
(vi)AWS Classification.
(8)(a) The electrodes shall be subjected to initial tests and periodic check tests to ensure that the requirements of these regulations are fulfilled.
(b)Electrodes intended for use with more than one type of current or polarity shall be tested using each type of current and polarity shall be tested using each type of current and polarity.
(c)Where any test specimen fails to satisfy the requirements of any particular test, two further test specimens shall be prepared using the electrodes from the same batch and submitted to the same test.
(d)The batch of electrodes shall be accepted as having passed the test provided that the tests of both the additional specimens are satisfactory.
(9)Test certificate provided by the manufacturer of covered electrode shall fulfil the requirements of the specification. The manufacturers, when called upon, shall produce the results of the most recent periodic check test carried out within the preceding 12 months, for electrodes supplied.
In short
Regulation 71 covers covered electrodes for shielded metal arc welding of carbon steel, low alloy steels, stainless steels and non-ferrous materials: their size, classification, covering, marking, storage and testing.
Key points
- (1) It applies to electrodes of 2.0 mm diameter and larger. The electrodes must give satisfactory welds in the hands of a welder of average skill, with listed characteristics such as stable arc, easy slag removal and low porosity.
- (2) Electrodes are classified as carbon steel, low alloy steel, stainless steel, or nickel and nickel-alloy, following ASME Part IIC SFA specifications, AWS specifications or equivalent.
- (3) Any manufacturing method may be used if the product meets these regulations and the relevant SFA or AWS specification.
- (4) Nominal size is the core wire diameter. Length must not exceed 450 mm. Tolerances: ± 0.05 mm on diameter and ±10 mm on length (or as per SFA/AWS).
- (5) Covering must be robust, uniform and concentric. Allowed eccentricity is 7 % of mean dimension up to 2.5 mm diameter, 5 % for 3.2 to 4.0 mm and 4 % for 5 mm and larger.
- (6) At least one classification imprint within 65 mm of the grip end, legible before and after welding.
- (7) Electrodes are stored in original packing in a dry store. They must perform as when dispatched for two years or the maker's recommended period, whichever is less. Beyond that, use may be permitted after check tests unless the maker restricts it. Packages are marked with maker, brand, size and quantity, batch and date, current range and AWS classification.
- (8) Initial and periodic check tests apply. If a specimen fails, two more from the same batch are tested, and both must pass.
- (9) On request, manufacturers produce the latest periodic check test results from the preceding 12 months.
Watch out
- Electrodes of less than 2.0 mm diameter must not be used in boilers.
- Electrodes meant for more than one type of current or polarity must be tested with each.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 8 | Welding | 100% | Chapter I (DPIIT scan), image 3 |
| 627 | Electrodes | 100% | Chapter XV (DPIIT scan), image 2 |
Amendment history of the candidate IBR 1950 regulations: Reg. 8 (2 amendments)
IBR 1950 regulation 8 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 8 page for its amendments.
| Reg. 8 Welding:- |
| (a) The use of welding in the construction of boilers shall be permitted only where specifically provided for in the standard conditions. |